Literature DB >> 1877676

Subendocardial coronary compression in beating dog hearts is independent of pressure in the ventricular lumen.

D M Van Winkle1, A N Swafford, J M Downey.   

Abstract

Ventricular decompression has been shown to have little effect on either the magnitude or transmural distribution of the extravascular resistance in the small hearts of the cat or rabbit. This study tests whether that independence from ventricular pressure also occurs in the large heart of the dog, which should be more representative of the human. We measured regional myocardial flow in each in situ dog heart during three conditions: normally beating, vented beating, and arrest. Hearts were perfused at constant pressure and maximally dilated with 0.4-1.0 mg/min ic adenosine. Total coronary blood flow was measured with an electromagnetic flowmeter, and regional flow was assessed with radiolabeled microspheres. Although arrest resulted in more than a doubling of flow to the inner layer, greatly reducing ventricular pressure by venting had no significant effect on subendocardial flow. Subepicardial flow was minimally affected by either venting or arrest. We conclude that both the magnitude and the transmural distribution of extravascular resistance in the large heart of the dog is unrelated to the pressure in the ventricular lumen.

Entities:  

Mesh:

Year:  1991        PMID: 1877676     DOI: 10.1152/ajpheart.1991.261.2.H500

Source DB:  PubMed          Journal:  Am J Physiol        ISSN: 0002-9513


  5 in total

Review 1.  Mechanical determinants of myocardial perfusion.

Authors:  J A Spaan
Journal:  Basic Res Cardiol       Date:  1995 Mar-Apr       Impact factor: 17.165

2.  Left ventricular pressure transmission to myocardial lymph vessels is different during systole and diastole.

Authors:  Y Han; I Vergroesen; M Goto; J Dankelman; C P Van der Ploeg; J A Spaan
Journal:  Pflugers Arch       Date:  1993-06       Impact factor: 3.657

3.  Systolic coronary flow reduction in the canine heart in situ: effects of left ventricular pressure and elastance.

Authors:  J Baan; P Steendijk; A Mikuniya; J Baan
Journal:  Basic Res Cardiol       Date:  1996 Nov-Dec       Impact factor: 17.165

4.  Coronary blood flow changes during atrioventricular sequential pacing with different atrioventricular delays in normal individuals.

Authors:  Z S Kyriakides; T M Kolettis; T Popov; T Mesiskli; K Triantafillou; D T Kremastinos
Journal:  J Interv Card Electrophysiol       Date:  1998-06       Impact factor: 1.900

Review 5.  The multi-scale modelling of coronary blood flow.

Authors:  Jack Lee; Nicolas P Smith
Journal:  Ann Biomed Eng       Date:  2012-05-08       Impact factor: 3.934

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.