Literature DB >> 18775664

[Brachytherapy at the Institut Gustave-Roussy: personalized vaginal mould applicator: technical modification and improvement].

M Albano1, I Dumas, C Haie-Meder.   

Abstract

Brachytherapy plays an important role in the treatment of patients with gynaecological cancers. At the Institut Gustave-Roussy, the technique of vaginal mould applicator has been used for decades. This technique allows a personalized tailored irradiation, integrating tumour shape, size and extension and vaginal anatomy. Vaginal expansion reduces the dose to the vaginal mucosa and to the organs at risk. We report a modification of the material used for vaginal mould manufacture. The advantages of the new material are a lighter weight, and transparency allowing a better accuracy in the placement of catheters for radioactive sources. This material is applicable for low dose-rate, pulse dose-rate and high dose-rate brachytherapy. Since 2001, more than 700 vaginal moulds have been manufactured with this new approach without any intolerance.

Entities:  

Mesh:

Year:  2008        PMID: 18775664     DOI: 10.1016/j.canrad.2008.04.002

Source DB:  PubMed          Journal:  Cancer Radiother        ISSN: 1278-3218            Impact factor:   1.018


  5 in total

1.  Adjuvant intravaginal brachytherapy for uterus didelphys with synchronous endometrial adenocarcinomas and unfavourable vaginal topography.

Authors:  Lucinda Morris; Mark John Stevens; Susan Valmadre; Judith Martland; Tony Lee
Journal:  Gynecol Oncol Case Rep       Date:  2012-07-20

2.  Adaptive 3D image-guided brachytherapy: a strong argument in the debate on systematic radical hysterectomy for locally advanced cervical cancer.

Authors:  Renaud Mazeron; Jennifer Gilmore; Isabelle Dumas; Jérôme Champoudry; Jennifer Goulart; Ben Vanneste; Anne Tailleur; Philippe Morice; Christine Haie-Meder
Journal:  Oncologist       Date:  2013-04-08

3.  Evaluation of PC-ISO for customized, 3D Printed, gynecologic 192-Ir HDR brachytherapy applicators.

Authors:  J Adam M Cunha; Katherine Mellis; Rajni Sethi; Timmy Siauw; Atchar Sudhyadhom; Animesh Garg; Ken Goldberg; I-Chow Hsu; Jean Pouliot
Journal:  J Appl Clin Med Phys       Date:  2015-01-08       Impact factor: 2.102

4.  The design of an individualized cylindrical vaginal applicator with oblique guide holes using 3D modeling and printing technologies.

Authors:  Zhipeng Zhao; Xiaodi Tang; Zhuang Mao; Hongfu Zhao
Journal:  J Contemp Brachytherapy       Date:  2019-10-30

5.  A single-institution review of image-guided brachytherapy for vaginal malignancies using customized molded applicators and interstitial needles.

Authors:  Emily Flower; Salman Zanjani; Gemma Busuttil; Emma Sullivan; Wayne Smith; Kathy Tran; David Thwaites; Jennifer Chard; Viet Do
Journal:  J Contemp Brachytherapy       Date:  2021-12-30
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.