Literature DB >> 1877439

Inability of coronary blood flow reserve measurements to assess the efficacy of coronary angioplasty in the first 24 hours in unselected patients.

G J Laarman1, P W Serruys, H Suryapranata, M vd Brand, P R Jonkers, P J de Feyter, J R Roelandt.   

Abstract

To determine functional and anatomic changes in the first 24 hours after coronary angioplasty, we studied at random 15 patients (9 men, mean age 60 years) who underwent coronary angioplasty of 16 coronary arteries. Quantitative coronary angiography and coronary flow reserve measurements from digitized coronary angiograms were performed before, immediately after, and 24 hours after coronary angioplasty. Calculated were the minimal luminal diameter, obstruction area, and percentage diameter stenosis from two preferably orthogonal projections. Prior myocardial infarction in the myocardial region of interest was present in four patients. Seven patients had multivessel disease. Collateral vessels supplying the compromised flow region were observed in three patients. Six patients had refractory unstable angina pectoris. After coronary angioplasty, angiographically visible dissection was noted in six patients, whereas side branch occlusion was observed in one. Minimal luminal diameter before, immediately after, and 24 hours after was 0.93 +/- 0.18 mm, 1.53 +/- 28 mm, and 1.53 +/- 0.21 mm, respectively; obstruction area was 0.70 +/- 0.26 mm2, 1.92 +/- 0.69 mm2, and 1.87 +/- 0.51 mm2, respectively; diameter stenosis was 60.4 +/- 8.0%, 36.8 +/- 11.4%, and 37.6 +/- 5.3%, respectively. The coronary flow reserve (lower limit of normal with this technique 3.4) was essentially the same before and immediately after coronary angioplasty (1.26 +/- 0.59 vs 1.30 +/- 0.42, p = NS) with a slight improvement to 1.78 +/- 0.90 (p less than 0.05) 1 day later. Coronary artery dimensions correlated poorly with coronary blood flow reserve before and after angioplasty.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1991        PMID: 1877439     DOI: 10.1016/0002-8703(91)90505-c

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  4 in total

1.  Improvement of coronary morphology and blood flow after stenting. Assessment by intravascular ultrasound and intracoronary Doppler.

Authors:  J Ge; R Erbel; J Zamorano; M Haude; P Kearney; G Görge; J Meyer
Journal:  Int J Card Imaging       Date:  1995-06

2.  Coronary flow reserve.

Authors:  P Collins
Journal:  Br Heart J       Date:  1993-04

Review 3.  Coronary microembolization--its role in acute coronary syndromes and interventions.

Authors:  R Erbel; G Heusch
Journal:  Herz       Date:  1999-11       Impact factor: 1.443

4.  Endothelium dependent and independent responses in coronary artery disease measured at angioplasty.

Authors:  D R Holdright; D Clarke; P A Poole-Wilson; K Fox; P Collins
Journal:  Br Heart J       Date:  1993-07
  4 in total