Literature DB >> 18773112

Liver resection with bipolar radiofrequency device: Habib 4X.

Madhava Pai1, Long R Jiao, Shirin Khorsandi, Ruben Canelo, Duncan R C Spalding, Nagy A Habib.   

Abstract

BACKGROUND: Intraoperative blood loss has been shown to be an important factor correlating with morbidity and mortality in liver surgery. In spite of the technological advances in hepatic parenchymal transection devices, bleeding remains the single most important complication of liver surgery. The role of radiofrequency (RF) in liver surgery has been expanded from tumour ablation to major hepatic resections in the last decade. Habib 4X, a new bipolar RF device designed specifically for liver resection is described here.
METHODS: Habib 4X is a bipolar, handheld, disposable RF device and consists of two pairs of opposing electrodes which is introduced perpendicularly into the liver, along the intended transection line. It produces controlled RF energy between the electrodes and the heat produced seals even major biliary and blood vessels and enables resection of the liver parenchyma with a scalpel without blood loss or biliary leak.
RESULTS: Three hundred and eleven patients underwent 384 liver resections from January 2002 to October 2007 with this device. There were 109 major resections and none of the patients had vascular inflow occlusion (Pringle's manoeuvre). Mean intraoperative blood loss was 305 ml (range 0-4300) ml, with less than 5% (n=18) rate of transfusion.
CONCLUSION: Habib 4X is an additional device for hepatobiliary surgeons to perform liver resections with minimal blood loss and low morbidity and mortality rates.

Entities:  

Keywords:  Habib 4X; blood loss; liver resection; parenchymal transection device; radiofrequency

Year:  2008        PMID: 18773112      PMCID: PMC2518308          DOI: 10.1080/13651820802167136

Source DB:  PubMed          Journal:  HPB (Oxford)        ISSN: 1365-182X            Impact factor:   3.647


  30 in total

1.  Liver resection using total vascular exclusion, scalpel division of the parenchyma, and a simple compression technique for hemostasis and biliary control.

Authors:  P D Hansen; A M Isla; N A Habib
Journal:  J Gastrointest Surg       Date:  1999 Sep-Oct       Impact factor: 3.452

2.  Hepatic resection using the harmonic scalpel.

Authors:  H Sugo; Y Mikami; F Matsumoto; H Tsumura; Y Watanabe; K Kojima; S Futagawa
Journal:  Surg Today       Date:  2000       Impact factor: 2.549

3.  Vascular occlusions for liver resections. Operative management and tolerance to hepatic ischemia: 142 cases.

Authors:  E Delva; Y Camus; B Nordlinger; L Hannoun; R Parc; H Deriaz; A Lienhart; C Huguet
Journal:  Ann Surg       Date:  1989-02       Impact factor: 12.969

4.  Intermittent vascular exclusion of the liver (without vena cava clamping) during major hepatectomy.

Authors:  D Elias; P Lasser; B Debaene; L Doidy; V Billard; A Spencer; B Leclercq
Journal:  Br J Surg       Date:  1995-11       Impact factor: 6.939

5.  Major liver resection without clamping: a prospective reappraisal in the era of modern surgical tools.

Authors:  Olivier Scatton; Pierre-Philippe Massault; Bertrand Dousset; Didier Houssin; Denis Bernard; Benoît Terris; Olivier Soubrane
Journal:  J Am Coll Surg       Date:  2004-11       Impact factor: 6.113

6.  Continuous versus intermittent portal triad clamping for liver resection: a controlled study.

Authors:  J Belghiti; R Noun; R Malafosse; P Jagot; A Sauvanet; F Pierangeli; J Marty; O Farges
Journal:  Ann Surg       Date:  1999-03       Impact factor: 12.969

7.  Reduction of transfusion requirements during major hepatic resection for metastatic disease.

Authors:  J P Arnoletti; J Brodsky
Journal:  Surgery       Date:  1999-02       Impact factor: 3.982

8.  Central venous pressure and its effect on blood loss during liver resection.

Authors:  R M Jones; C E Moulton; K J Hardy
Journal:  Br J Surg       Date:  1998-08       Impact factor: 6.939

9.  Bloodless liver resection using the monopolar floating ball plus ligasure diathermy: preliminary results of 16 liver resections.

Authors:  Yoshihiro Sakamoto; Junji Yamamoto; Norihiro Kokudo; Makoto Seki; Tomoo Kosuge; Toshiharu Yamaguchi; Tetsuichiro Muto; Masatoshi Makuuchi
Journal:  World J Surg       Date:  2004-01-08       Impact factor: 3.352

10.  Influence of transfusions on perioperative and long-term outcome in patients following hepatic resection for colorectal metastases.

Authors:  David A Kooby; Jennifer Stockman; Leah Ben-Porat; Mithat Gonen; William R Jarnagin; Ronald P Dematteo; Scott Tuorto; David Wuest; Leslie H Blumgart; Yuman Fong
Journal:  Ann Surg       Date:  2003-06       Impact factor: 12.969

View more
  16 in total

1.  A novel technique of partial splenectomy using radiofrequency ablation.

Authors:  Jan Jin Bong; Rajesh Kumar; Duncan Spalding
Journal:  J Gastrointest Surg       Date:  2010-09-09       Impact factor: 3.452

Review 2.  Radiofrequency energy in surgery: state of the art.

Authors:  Peter Ihnát; Lucia Ihnát Rudinská; Pavel Zonča
Journal:  Surg Today       Date:  2013-06-01       Impact factor: 2.549

3.  Laparoscopic treatment of liver tumours using a two-needle probe bipolar radiofrequency ablation device.

Authors:  Farzad Alemi; Edwin Kwon; Jonathan Chiu; Hisae Aoki; Lygia Stewart; Carlos U Corvera
Journal:  HPB (Oxford)       Date:  2011-07-13       Impact factor: 3.647

Review 4.  Recent advances in multidisciplinary management of hepatocellular carcinoma.

Authors:  Asmaa I Gomaa; Imam Waked
Journal:  World J Hepatol       Date:  2015-04-08

5.  Partial spleen resection with a radiofrequency needle device--a pilot study.

Authors:  Juliane Liese; Sven Kohler; Christian Moench; Wolf Otto Bechstein; Frank Ulrich
Journal:  Langenbecks Arch Surg       Date:  2013-02-06       Impact factor: 3.445

6.  Radiofrequency-assisted versus clamp-crushing parenchyma transection in cirrhotic patients with hepatocellular carcinoma: a randomized clinical trial.

Authors:  Min Li; Wei Zhang; Yi Li; Peizhi Li; Jinzheng Li; Jianping Gong; Yongjun Chen
Journal:  Dig Dis Sci       Date:  2012-09-25       Impact factor: 3.199

7.  Efficiency and safety of radiofrequency-assisted hepatectomy for hepatocellular carcinoma with cirrhosis: A single-center retrospective cohort study.

Authors:  Fan Zhang; Jun Yan; Xiao-Bin Feng; Feng Xia; Xiao-Wu Li; Kuan-Sheng Ma; Ping Bie
Journal:  World J Gastroenterol       Date:  2015-09-21       Impact factor: 5.742

8.  Radiofrequency on the liver remnant after liver resection to reach the haemostasis not otherwise achievable with conventional techniques.

Authors:  Benedetta Pesi; Francesca Leo; Gadiel Liscia; Giovanni Alemanno; Daniela Zambonin; Massimo Falchini; Giacomo Batignani
Journal:  Int J Surg Case Rep       Date:  2013-04-04

9.  Radiofrequency-induced small bowel thermofusion: an ex vivo study of intestinal seal adequacy using mechanical and imaging modalities.

Authors:  Shobhit Arya; Nancy Hadjievangelou; Su Lei; Hiromi Kudo; Robert D Goldin; Ara W Darzi; Daniel S Elson; George B Hanna
Journal:  Surg Endosc       Date:  2013-04-10       Impact factor: 4.584

10.  Bleeding in Hepatic Surgery: Sorting through Methods to Prevent It.

Authors:  Fabrizio Romano; Mattia Garancini; Fabio Uggeri; Luca Degrate; Luca Nespoli; Luca Gianotti; Angelo Nespoli; Franco Uggeri
Journal:  HPB Surg       Date:  2012-11-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.