Literature DB >> 18772591

Real-time glucose sensors in children and adolescents with type-1 diabetes.

Thomas Danne1, Karin Lange, Olga Kordonouri.   

Abstract

The increased availability of continuous glucose sensors is likely to have a significant impact on pediatric diabetes therapy and education in the future. While a recent meta-analysis of retrospective first-generation Holter-type sensors was not able to show advantages compared to self-monitoring of blood glucose levels, this review focuses on current real-time sensors. Our own experience with 23 children aged 10 (3-15) years with sensor-augmented pump therapy showed high ratings for overall satisfaction and ease of use of the system (5.8 on a 7 point Likert scale). The results of our ongoing international pediatric ONSET trial will show the impact of this technology on learning to live with diabetes by having the biofeedback of glucose excursions from the onset of diabetes. Families previously relying on self-monitoring of blood glucose need to understand the difference between estimating the absolute blood glucose value (point accuracy) and the change in blood glucose (rate accuracy), and how to take into consideration the inherent interstitial time lag. Selection of patients capable and motivated to use continuous sensors accompanied with proper age-appropriate education remain key factors for the long-term success of these new technological advances in diabetes therapy as long as closed loop systems are not available. Copyright 2008 S. Karger AG, Basel.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18772591     DOI: 10.1159/000151592

Source DB:  PubMed          Journal:  Horm Res        ISSN: 0301-0163


  5 in total

Review 1.  Therapeutics of diabetes mellitus: focus on insulin analogues and insulin pumps.

Authors:  Vasiliki Valla
Journal:  Exp Diabetes Res       Date:  2010-05-26

2.  A MEMS affinity glucose sensor using a biocompatible glucose-responsive polymer.

Authors:  Xian Huang; Siqi Li; Jerome S Schultz; Qian Wang; Qiao Lin
Journal:  Sens Actuators B Chem       Date:  2009-07-16       Impact factor: 7.460

Review 3.  Influences on Technology Use and Efficacy in Type 1 Diabetes.

Authors:  Victoria Franklin
Journal:  J Diabetes Sci Technol       Date:  2016-05-03

4.  Reducing glycaemic variability in type 1 diabetes self-management with a continuous glucose monitoring system based on wired enzyme technology.

Authors:  T Danne; H W de Valk; T Kracht; K Walte; R Geldmacher; L Sölter; W von dem Berge; Z K Welsh; J R Bugler; K Lange; O Kordonouri
Journal:  Diabetologia       Date:  2009-06-13       Impact factor: 10.122

5.  Measurement delay associated with the Guardian RT continuous glucose monitoring system.

Authors:  C Wei; D J Lunn; C L Acerini; J M Allen; A M Larsen; M E Wilinska; D B Dunger; R Hovorka
Journal:  Diabet Med       Date:  2010-01       Impact factor: 4.359

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.