Literature DB >> 18772119

Sizing of atrial septal defects by intracardiac echocardiography for device closures.

Jen-Chung Chien1, Betau Hwang, Yun-Ching Fu, Pi-Chang Lee, Kai-Sheng Hsieh, Sheng-Ling Jan.   

Abstract

BACKGROUND: Transcatheter closure of a secundum atrial septal defect (ASD) has become an effective method for surgical treatment. In this study, we evaluated the feasibility and accuracy of intracardiac echocardiography (ICE) for sizing ASDs compared with conventional methods.
METHODS: Between January 2004 and December 2006, 270 patients underwent transcatheter closure of secundum ASD by using septal occluders. For 142 patients, the procedure was guided by transesophageal echocardiography (TEE), and for 128 patients by ICE. We compared the maximal diameters of the ASDs obtained during angiocardiography, transthoracic echocardiography (TTE), ICE, and TEE with balloon-stretched sizes ascertained by using a sizing plate.
RESULTS: ASD diameters measured with the sizing plate were significantly correlated with those measured with ICE (r = 0.963), TEE (r = 0.912), angiography (r = 0.88), and TTE (r = 0.85). The predicted stretched diameter of the ASDs, i.e. (nonstretched diameter measured with ICE x 1.07) + 3.23 mm, agreed well with that measured by using a sizing plate (Ri = 0.974).
CONCLUSION: ASD diameters measured with ICE correlated with sizing-plate measurements better than those determined with TEE, angiography or TTE.

Entities:  

Mesh:

Year:  2008        PMID: 18772119     DOI: 10.1016/S1726-4901(08)70090-X

Source DB:  PubMed          Journal:  J Chin Med Assoc        ISSN: 1726-4901            Impact factor:   2.743


  3 in total

1.  Safety and feasibility of intra-operative device closure of atrial septal defect with transthoracic minimal invasion.

Authors:  Qiang Chen; Hua Cao; Gui-Can Zhang; Liang-Wan Chen; Dao-Zhong Chen
Journal:  Eur J Cardiothorac Surg       Date:  2012-01       Impact factor: 4.191

2.  Enlargement Ratio May Predict Device Size in Elderly Patients with Atrial Septal Defect.

Authors:  Semi Ozturk; Ahmed Seyfettin Gurbuz; Suleyman Cagan Efe; Mehmet Fatih Yılmaz; Cevat Kırma
Journal:  Korean Circ J       Date:  2017-09-11       Impact factor: 3.243

3.  A comparison between size of the occluder device and two-dimensional transoesophageal echocardiographic sizing of the ostium secundum atrial septal defect.

Authors:  Alimohammad Hajizeinali; Hakimeh Sadeghian; Mehrnaz Rezvanfard; Mohammad Alidoosti; Arezoo Zoroufian; Marat A Volman
Journal:  Cardiovasc J Afr       Date:  2013-06       Impact factor: 1.167

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.