Literature DB >> 18771555

Evaluation of the left ventricular diastolic function using three-dimensional echocardiography.

Hideki Tashiro1, Takiko Aoki, Kenji Sadamatsu, Kensuke Ooe, Tohru Yamawaki, Shuichirou Sagara.   

Abstract

UNLABELLED: The aim of this study was to evaluate the left ventricular (LV) diastolic function parameter calculated using three-dimensional (3D) echocardiography.
METHOD: Using 3D echocardiography and an analysis software program, the left ventricular volume through the cardiac cycle was measured automatically. We therefore calculated 25%, 50%, and 75% of the subtraction end-systolic volume (ESV) from the end-diastolic volume (EDV). The period that the left ventricular volume reached those volumes was calculated from the ESV. Those periods divided all diastolic periods and those calculated values were named D1/4, D1/2, and D3/4, respectively. The peak-filling rate and 1/3 filling fraction (FF) were calculated. E/A, mitral annulus velocities (E'), E/E', ejection fraction (EF), and left ventricular end-diastolic pressure (LVEDP) were also measured.
RESULTS: E/A significantly correlated with D3/4. E/E'significantly correlated with the D1/4, D1/2, and 1/3 filling fraction. E'had a significantly negative correlation with the D1/4, D1/2, D3/4, and 1/3 FF. DT significantly correlated with D1/4, D1/2, D3/4, 1/3 FF, and the mean filling rate and it had a significant negative correlation with the 1/3 filling fraction. EF showed a significant positive correlation with the peak filling ratio. LVEDP demonstrated a significant correlation with D1/4 and D1/2.
CONCLUSION: This study suggests that the LV diastolic indexes as determined by 3D echocardiography provide useful information in the clinical assessment of the diastolic LV function.

Entities:  

Mesh:

Year:  2008        PMID: 18771555     DOI: 10.1111/j.1540-8175.2008.00716.x

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  3 in total

1.  Three-dimensional echocardiographic quantitative evaluation of left ventricular diastolic function using analysis of chamber volume and myocardial deformation.

Authors:  Chattanong Yodwut; Roberto M Lang; Lynn Weinert; Homaa Ahmad; Victor Mor-Avi
Journal:  Int J Cardiovasc Imaging       Date:  2012-06-30       Impact factor: 2.357

2.  Impact of transcatheter closure of atrial septal defects on cardiac function.

Authors:  Hideki Tashiro; Kenji Suda; Yoshifumi Tananari; Shinichi Itou
Journal:  J Med Ultrason (2001)       Date:  2012-03-09       Impact factor: 1.314

3.  Machine learning based automated dynamic quantification of left heart chamber volumes.

Authors:  Akhil Narang; Victor Mor-Avi; Aldo Prado; Valentina Volpato; David Prater; Gloria Tamborini; Laura Fusini; Mauro Pepi; Neha Goyal; Karima Addetia; Alexandra Gonçalves; Amit R Patel; Roberto M Lang
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2019-05-01       Impact factor: 6.875

  3 in total