Maintenance of platelet in vitro properties during 7-day storage in M-sol with a 30-hour interruption of agitation.

Stephen J Wagner1, Andrew Myrup, Helen Awatefe, Dedeene Thompson-Montgomery, Junichi Hirayama, Andrey Skripchenko.   

Abstract

BACKGROUND: Extensive periods without agitation can occasionally occur during platelet (PLT) shipment and can affect PLT quality during 5- to 7-day storage. The use of buffer-containing PLT additive solutions (ASs) may better preserve PLT quality during storage by maintaining PLT pH and other in vitro variables. A newly described bicarbonate-containing AS, M-sol, was compared to plasma for preservation of whole blood-derived PLT concentrates in which a 30-hour interruption of agitation was included. STUDY DESIGN AND METHODS: ABO-identical PLT-rich plasma intermediate products were pooled in sets of four, split, and centrifuged with subsequent plasma expression (n = 12). Two units were resuspended with M-sol AS to produce a 70 percent solution/30 percent plasma PLT concentrate; 2 units were resuspended in 100 percent plasma. One M-sol resuspended unit and 1 plasma unit were held on a laboratory bench in a standard shipping box for 30 hours between Day 2 and Day 3, while the other M-sol and plasma unit were continuously agitated. Standard in vitro testing for PLT quality variables on each set of 4 units was performed during storage (n = 12).
RESULTS: Interrupting agitation of PLTs suspended in M-sol resulted in less of a pH decrement during storage than that of PLTs suspended in 100 percent plasma. On Days 5 and 7, the pH differences between M-sol and plasma units were 0.56 and 0.75 pH units, respectively (p < 0.0003). In addition, PLTs suspended in M-sol and subjected to an interruption of agitation had lesser Day 7 CD62+ cells, glucose utilization, and lactate production and greater hypotonic stress response, morphology, swirling, and aggregation response than those suspended in plasma (p </= 0.005).
CONCLUSION: The in vitro properties of PLTs suspended in 70 percent M-sol/30 percent plasma and subjected to a 30-hour interruption of agitation are better maintained during 7-day storage than those of matched units suspended in plasma.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18764828     DOI: 10.1111/j.1537-2995.2008.01900.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  2 in total

1.  Influence of apheresis collection device and container on the storage properties of platelets in 90% PAS-5/10% plasma.

Authors:  Stephen J Wagner; Cheryl A Hapip; Annette Turgeon; Lenora Abel; Nadine Kaelber
Journal:  Blood Transfus       Date:  2018-09-05       Impact factor: 3.443

2.  In vitro properties of concentrated canine platelets stored in two additive solutions: a comparative study.

Authors:  N Hlavac; C S Lasta; M L Dalmolin; L A Lacerda; D de Korte; N A Marcondes; S R Terra; F B Fernandes; F H D González
Journal:  BMC Vet Res       Date:  2017-11-15       Impact factor: 2.741