Effect of solution concentration, surface bias and protonation on the dynamic response of amplitude-modulated atomic force microscopy in water.

Yan Wu1, Chaitanya Gupta, Mark A Shannon.   

Abstract

The dynamic response of amplitude-modulated atomic force microscopy (AM-AFM) is studied at the solid/water interface with respect to changes in ionic concentration, applied surface potential, and surface protonation. Each affects the electric double layer in the solution, charge on the tip and the sample surface, and thus the forces affecting the dynamic response. A theoretical model is developed to relate the effective stiffness and hydrodynamic damping of the AFM cantilever that is due to the tip/surface interaction with the phase and amplitude signals measured in the AM-AFM experiments. The phase and amplitude of an oscillating cantilever are measured as a function of tip-sample distance in three experiments: mica surface in potassium nitrate solutions with different concentrations, biased gold surface in potassium nitrate solution, and carboxylic acid-terminated self-assembled monolayers (SAMs) on gold in potassium nitrate pH buffers. Results show that, over the range where the higher harmonic modes of the oscillation are negligible, the effective stiffness of the AFM cantilever increases to a maximum as the tip approaches the surface before declining again as a result of the repulsive electrical double layer interaction. For attractive electrical double-layer interactions, the effective stiffness declines monotonically as the tip approaches the surface. Similarly, the hydrodynamic damping of the tip increases and then decreases as the tip approaches the solid/water interface, with the magnitude depending on the species present in the solution.

Entities:  

Year:  2008        PMID: 18763814     DOI: 10.1021/la801295c

Source DB:  PubMed          Journal:  Langmuir        ISSN: 0743-7463            Impact factor:   3.882


  2 in total

1.  Measuring Electric Charge and Molecular Coverage on Electrode Surface from Transient Induced Molecular Electronic Signal (TIMES).

Authors:  Ping-Wei Chen; Chi-Yang Tseng; Fumin Shi; Bo Bi; Yu-Hwa Lo
Journal:  Sci Rep       Date:  2019-11-07       Impact factor: 4.379

Review 2.  Integration of biosensors and drug delivery technologies for early detection and chronic management of illness.

Authors:  Mpho Ngoepe; Yahya E Choonara; Charu Tyagi; Lomas Kumar Tomar; Lisa C du Toit; Pradeep Kumar; Valence M K Ndesendo; Viness Pillay
Journal:  Sensors (Basel)       Date:  2013-06-14       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.