An on-line solid phase extraction method for the preconcentration and determination of Cu(II) by flame atomic absorption spectrometry (FAAS) has been described. It is based on the adsorption of copper(II) ion onto a home made mini column of Chromosorb 105 resin loaded with pyrocatechol violet at the pH range of 5.0-8.0, then eluted with 1 mol L(-1) HNO(3). Several parameters, such as pH of the sample solution, amount of Chromosorb 105 resin, volume of sample and eluent, type of eluent, flow rates of sample and eluent, governing the efficiency and throughput of the method were evaluated. The concentration of the copper ion detected after preconcentration was in agreement with the added amount. At optimized conditions, for 15 min of preconcentration time (30 mL of sample volume), the system achieved a detection limit of 0.02 microg L(-1), with relative standard deviation 1.1% at 0.03 microg mL(-1) copper. The present method was found to be applicable to the preconcentration of Cu(II) in natural water samples.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18762371     DOI: 10.1016/j.jhazmat.2008.07.096

Source DB:  PubMed          Journal:  J Hazard Mater        ISSN: 0304-3894            Impact factor:   10.588


  4 in total

1.  Vortex assisted solid-phase extraction of lead(II) using orthorhombic nanosized Bi2WO6 as a sorbent.

Authors:  Neda Baghban; Erkan Yilmaz; Mustafa Soylak
Journal:  Mikrochim Acta       Date:  2017-12-07       Impact factor: 5.833

2.  Solid phase extraction and preconcentration of Cu(II), Pb(II), and Ni(II) in environmental samples on chemically modified Amberlite XAD-4 with a proper Schiff base.

Authors:  Berrin Topuz; Mustafa Macit
Journal:  Environ Monit Assess       Date:  2010-03-18       Impact factor: 2.513

3.  Solid phase extraction of Cd, Pb, Ni, Cu, and Zn in environmental samples on multiwalled carbon nanotubes.

Authors:  Erkan Yilmaz; Mustafa Soylak
Journal:  Environ Monit Assess       Date:  2014-05-09       Impact factor: 2.513

4.  Vortex-assisted low density solvent and surfactant based dispersive liquid-liquid microextraction for sensitive spectrophotometric determination of cobalt.

Authors:  Patiwat Chaiyamate; Ketsarin Seebunrueng; Supalax Srijaranai
Journal:  RSC Adv       Date:  2018-02-14       Impact factor: 3.361