Literature DB >> 18761576

Effects of thermocycling on the tensile bond strength of three permanent soft denture liners.

Daniela Maffei Botega1, José Luiz Lopes Sanchez, Marcelo Ferraz Mesquita, Guilherme Elias Pessanha Henriques, Rafael Leonardo Xediek Consani.   

Abstract

PURPOSE: This study investigated the effect of in vitro accelerated aging reproduced with thermocycling on the bond strength of three commercially available permanent denture soft liners (PermaSoft, Dentuflex, Ufi-gel) with one heat-polymerized polymethyl methacrylate resin denture base (QC-20) by tensile test.
MATERIAL AND METHODS: Ten specimens were prepared for control and test groups of each material for a total of 60 specimens. All controls were stored in water (37 degrees C) for 24 hours before testing. All test groups received 3000 thermal cycles consisting of 1 minute at 5 degrees C and 1 minute at 65 degrees C. All specimens were submitted to a tensile test using a universal testing machine at a crosshead speed of 5 mm/min. Results were statistically analyzed (ANOVA, p < or = 0.05, Tukey's post-hoc test).
RESULTS: The mean bond strength of control specimens was (MPa): 0.32 (Ufi-gel), 0.49 (PermaSoft), and 1.19 (Dentuflex). There was no statistical difference (p > 0.05) between Ufi-gel and PermaSoft, but both were statistically different (p < 0.05) when compared to Dentuflex. After thermocycling, the mean bond strength was (MPa): 0.18 (Ufi-gel), 0.81 (PermaSoft), and 3.32 (Dentuflex). All materials were statistically different (p < 0.05). Ufi-gel had the lowest value and Dentuflex the highest in both control and test groups. Dentuflex presented only adhesive failure; in the remaining groups, there was no predominant failure mode, except Ufi-gel control with no adhesive failure.
CONCLUSIONS: Despite presenting greater bond strength, thermocycling had a deleterious effect in Dentuflex; Ufi-gel may be adequate for short-term use.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18761576     DOI: 10.1111/j.1532-849X.2008.00342.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  9 in total

1.  Tensile bond strength of silicone-based soft denture liner to two chemically different denture base resins after various surface treatments.

Authors:  Hakan Akin; Faik Tugut; Umit Guney; Omer Kirmali; Turker Akar
Journal:  Lasers Med Sci       Date:  2012-03-25       Impact factor: 3.161

2.  Effect of different surface treatments on tensile bond strength of silicone-based soft denture liner.

Authors:  Hakan Akin; Faik Tugut; Burcu Mutaf; Gulsah Akin; A Kemal Ozdemir
Journal:  Lasers Med Sci       Date:  2010-08-21       Impact factor: 3.161

3.  Strength of the bond between a silicone lining material and denture resin after Er:YAG laser treatments with different pulse durations and levels of energy.

Authors:  Faik Tugut; Hakan Akin; Burcu Mutaf; Gulsah Emine Akin; Ali Kemal Ozdemir
Journal:  Lasers Med Sci       Date:  2010-12-14       Impact factor: 3.161

4.  Investigation of bonding properties of denture bases to silicone-based soft denture liner immersed in isobutyl methacrylate and 2-hydroxyethyl methacrylate.

Authors:  Hakan Akin; Faik Tugut; Burcu Mutaf; Umit Guney
Journal:  J Adv Prosthodont       Date:  2014-04-22       Impact factor: 1.904

5.  Effect of Pre-heating on Microtensile Bond Strength of Composite Resin to Dentin.

Authors:  Abdolrahim Davari; Alireza Daneshkazemi; Behnaz Behniafar; Mahsan Sheshmani
Journal:  J Dent (Tehran)       Date:  2014-09-30

6.  Effect of Ozone and Two Common Denture Cleaners on Tensile Bond Strength and Surface Hardness of a Silicone Soft Liner.

Authors:  Mohammadreza Nakhaei; Amirtaher Mirmortazavi; Mansooreh Ghanbari; Zahra Ahmadi
Journal:  Front Dent       Date:  2019-10-15

7.  Antifungal Efficacy of a Permanent Silicon Soft Liner Containing Silver Nanoparticles.

Authors:  Sareh Habibzadeh; Solmauz Eskandarion; Seyed Mahmoud Amin Marashi; Ghazal Yunesi; Mohamadjavad Kharazifard
Journal:  Front Dent       Date:  2021-04-05

8.  The effect of thermocycling on tensile bond strength of two soft liners.

Authors:  Farideh Geramipanah; Masoumeh Ghandari; Somayeh Zeighami
Journal:  J Dent (Tehran)       Date:  2013-09-30

9.  Comparative evaluation of shear bond strength of two different chairside soft liners to heat processed acrylic denture base resin: An in vitro study.

Authors:  N Rajaganesh; S Sabarinathan; N S Azhagarasan; Chitra Shankar; Jaya Krishnakumar; S Swathi
Journal:  J Pharm Bioallied Sci       Date:  2016-10
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.