Shear bond strength of four resin cements used to lute ceramic core material to human dentin.

Subutayhan Altintas1, Ayçe Unverdi Eldeniz, Aslihan Usumez.   

Abstract

PURPOSE: This study evaluated the effect of four resin cements on the shear bond strength of a ceramic core material to dentin.
MATERIALS AND METHODS: One hundred twenty molar teeth were embedded in a self-curing acrylic resin. The occlusal third of the crowns were sectioned under water cooling. All specimens were randomly divided into four groups of 30 teeth each according to the resin cement used. One hundred twenty cylindrical-shaped, 2.7-mm wide, 3-mm high ceramic core materials were heat-pressed. The core cylinders were then luted with one of the four resin systems to dentin (Super-Bond C&B, Chemiace II, Variolink II, and Panavia F). Half of the specimens (n = 15) were tested after 24 hours; the other half (n = 15) were stored in distilled water at 37 degrees C for 1 day and then thermocycled 1000 times between 5 degrees C and 55 degrees C prior to testing. Shear bond strength of each specimen was measured using a universal testing machine at a crosshead speed of 1 mm/min. The bond strength values were calculated in MPa, and the results were statistically analyzed using a two-way analysis of variance (ANOVA) and Tukey HSD tests.
RESULTS: The shear bond strength varied significantly depending on the resin cement used (p < 0.05). The differences in the bond strengths after thermocycling were not remarkable as compared with the corresponding prethermal cycling groups (p > 0.05). Significant interactions were present between resin cement and thermocycling (p < 0.05). After 24 hours, the specimens luted with Variolink II (5.3 +/- 2.2 MPa) showed the highest shear bond strength, whereas the specimens luted with Chemiace II (1.6 +/- 0.4 MPa) showed the lowest. After thermocycling, the bond strength values of specimens luted with Chemiace II (1.1 +/- 0.1 MPa) and Super-Bond C&amp;B (1.7 +/- 0.4 MPa) decreased; however, this was not statistically significant (p > 0.05). The increase in the shear bond strength values in the Panavia F (4.5 +/- 0.7 MPa) and Variolink II (5.5 +/- 2.1 MPa) groups after thermocycling was also not statistically significant (p > 0.05).
CONCLUSION: Variolink II and Panavia F systems showed higher shear bond strength values than Chemiace II and Super-Bond C&amp;B. They can be recommended for luting ceramic cores to dentin surfaces.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18761570     DOI: 10.1111/j.1532-849X.2008.00348.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  7 in total

1.  Chronic detachable headphones for acoustic stimulation in freely moving animals.

Authors:  Fernando R Nodal; Peter Keating; Andrew J King
Journal:  J Neurosci Methods       Date:  2010-03-25       Impact factor: 2.390

2.  Improvement of enamel bond strengths for conventional and resin-modified glass ionomers: acid-etching vs. conditioning.

Authors:  Ling Zhang; Tian Tang; Zhen-liang Zhang; Bing Liang; Xiao-miao Wang; Bai-ping Fu
Journal:  J Zhejiang Univ Sci B       Date:  2013-11       Impact factor: 3.066

3.  The effect of repeated bonding on the shear bond strength of different resin cements to enamel and dentin.

Authors:  Ali Can Bulut; Saadet Sağlam Atsü
Journal:  J Adv Prosthodont       Date:  2017-02-07       Impact factor: 1.904

4.  Comparative analysis of shear bond strength of lithium disilicate samples cemented using different resin cement systems: An in vitro study.

Authors:  Viram Upadhyaya; Aman Arora; Jagriti Singhal; Smriti Kapur; Monika Sehgal
Journal:  J Indian Prosthodont Soc       Date:  2019 Jul-Sep

5.  Comparative Evaluation of Shear Bond Strength of Newer Resin Cement (RelyX Ultimate and RelyX U200) to Lithium Disilicate and Zirconia Ceramics as Influenced by Thermocycling.

Authors:  Rinki Kansal; Sapna Rani; Manoj Kumar; Shalabh Kumar; Gaurav Issar
Journal:  Contemp Clin Dent       Date:  2018 Oct-Dec

6.  Shear Bond Strength of E. Max Ceramic Restoration to Hydraulic Calcium Silicate Based Cement (Biodentine): An In Vitro Study.

Authors:  Kholod Khalil Al-Manei; Asma Ban Owaiwid; Reem AlDhafiri; Khaled Al-Manei; Shahad AlHarran; Reem Alsulaimani
Journal:  Eur Endod J       Date:  2020-12

Review 7.  Cementation of Glass-Ceramic Posterior Restorations: A Systematic Review.

Authors:  Carline R G van den Breemer; Marco M M Gresnigt; Marco S Cune
Journal:  Biomed Res Int       Date:  2015-10-18       Impact factor: 3.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.