Leigh A Hale1, Jaya Pal, Ines Becker. 1. REAL Neurology Research Group, Centre for Physiotherapy Research and School of Physiotherapy, University of Otago, Dunedin, New Zealand. leigh.hale@otago.ac.nz
Abstract
OBJECTIVE: To investigate the reliability, validity, and utility of a triaxial accelerometer to measure physical activity in the free-living environment in adults with and without neurologic dysfunction. DESIGN: Repeated-measures design. SETTING: General community. PARTICIPANTS: Volunteer sample of 17 men and 30 women (age range, 28-91y) living in the community with stroke of greater than 6 months in duration (n=20), Parkinson disease (n=7), or multiple sclerosis (n=11), and healthy but sedentary controls (n=9). INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Physical activity measured with the TriTrac RT3 accelerometer, 7-day recall questionnaire, and activity diary. RESULTS: The accelerometer reliably measured free-living physical activity (intraclass correlation coefficient, .85; 95% confidence interval, .74-.91; P=.000). The standard error of measurement indicated that a second test would differ from a baseline test by +/-23%. Mean daily RT3 data collected in the first 3 days differed significantly from that of the mean daily RT3 data collected over 7 days. The RT3 appeared to distinguish level of mobility better than the 7-day recall questionnaire, and participants found the RT3 to be a user-friendly and acceptable measure of physical activity. CONCLUSIONS: The triaxial accelerometer provided a stable measure of free-living physical activity, was found to distinguish between people with varying levels of mobility, and was well tolerated by participants. The results indicate that collecting data for 3 days was not reflective of data collected over 7 days.
OBJECTIVE: To investigate the reliability, validity, and utility of a triaxial accelerometer to measure physical activity in the free-living environment in adults with and without neurologic dysfunction. DESIGN: Repeated-measures design. SETTING: General community. PARTICIPANTS: Volunteer sample of 17 men and 30 women (age range, 28-91y) living in the community with stroke of greater than 6 months in duration (n=20), Parkinson disease (n=7), or multiple sclerosis (n=11), and healthy but sedentary controls (n=9). INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Physical activity measured with the TriTrac RT3 accelerometer, 7-day recall questionnaire, and activity diary. RESULTS: The accelerometer reliably measured free-living physical activity (intraclass correlation coefficient, .85; 95% confidence interval, .74-.91; P=.000). The standard error of measurement indicated that a second test would differ from a baseline test by +/-23%. Mean daily RT3 data collected in the first 3 days differed significantly from that of the mean daily RT3 data collected over 7 days. The RT3 appeared to distinguish level of mobility better than the 7-day recall questionnaire, and participants found the RT3 to be a user-friendly and acceptable measure of physical activity. CONCLUSIONS: The triaxial accelerometer provided a stable measure of free-living physical activity, was found to distinguish between people with varying levels of mobility, and was well tolerated by participants. The results indicate that collecting data for 3 days was not reflective of data collected over 7 days.
Authors: Vrutangkumar V Shah; James McNames; Martina Mancini; Patricia Carlson-Kuhta; Rebecca I Spain; John G Nutt; Mahmoud El-Gohary; Carolin Curtze; Fay B Horak Journal: J Neurol Date: 2020-01-11 Impact factor: 4.849
Authors: Deirdre A Hurley; Jennifer Eadie; Grainne O'Donoghue; Clare Kelly; Chris Lonsdale; Suzanne Guerin; Mark A Tully; Willem van Mechelen; Suzanne M McDonough; Colin A G Boreham; Conor Heneghan; Leslie Daly Journal: BMC Musculoskelet Disord Date: 2010-04-16 Impact factor: 2.362
Authors: Paul Hendrick; Stephan Milosavljevic; Melanie L Bell; Leigh Hale; Deirdre A Hurley; Suzanne M McDonough; Markus Melloh; David G Baxter Journal: BMC Musculoskelet Disord Date: 2009-11-06 Impact factor: 2.362