Diaphragmatic myopotential oversensing in pacemaker-dependent patients with CRT-D devices.

Katya Reis Santos1, Pedro Adragão, Diogo Cavaco, Francisco Bello Morgado, Rui Candeias, Sónia Lima, José Aniceto Silva.   

Abstract

AIMS: To evaluate the incidence and clinical significance of diaphragmatic myopotential (dMP) oversensing in pacemaker (PM)-dependent patients with CRT-Ds. METHODS AND
RESULTS: We retrospectively evaluated patients with CRT-Ds implanted at our institution between January 2000 and August 2006. PM-dependent patients were identified, and the incidence of inappropriate detections due to dMP oversensing and their possible clinical implications (inappropriate therapies, syncope, and death of any cause) were evaluated. CRT-Ds were implanted in 122 patients, 37 were or became PM dependent. During a mean follow-up of 22 +/- 17 months, 7(18.9%) PM-dependent patients revealed inappropriate detections due to dMP oversensing. All oversensing episodes occurred in CRT-Ds with automatic gain control (AGC) sensing and integrated bipolar (IBP) leads in the RV apex. These detections led to inappropriate shocks in 2(5.4%) patients and syncope in 1(2.7%). Five (13.5%) patients died.
CONCLUSION: dMP oversensing in PM-dependent patients with CRT-Ds is an important problem, particularly in CRT-Ds with AGC sensing and IBP leads, with over 20% of patients with these devices revealing inappropriate detections. The clinical impact of dMP oversensing is less marked but relevant, with both inappropriate therapies and syncope occurring in this small group of 37 patients and the possibility of related deaths.

Entities:  

Mesh:

Year:  2008        PMID: 18757865     DOI: 10.1093/europace/eun241

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  5 in total

1.  Surface electromyography of myopotential oversensing provoked by simultaneous straining and leftward twisting in a patient with an implantable cardioverter defibrillator.

Authors:  Yoichi Ajiro; Tsuyoshi Shiga; Morio Shoda; Nobuhisa Hagiwara
Journal:  Heart Vessels       Date:  2016-08-30       Impact factor: 2.037

Review 2.  Enhancing Cardiac Resynchronization Therapy for Patients with Atrial Fibrillation: The Role of AV Node Ablation.

Authors:  Jeff M Berry; Jose AJoglar
Journal:  J Atr Fibrillation       Date:  2012-04-14

3.  Myopotential oversensing notified by Lead Integrity Alert in a patient with implantable cardioverter defibrillator with a dedicated bipolar epicardial sensing lead.

Authors:  Kyoichiro Yazaki; Yoichi Ajiro; Shun Hasegawa; Masahiro Watanabe; Kei Tsukamoto; Keiko Mizobuchi; Takashi Saito; Fumiaki Mori; Kazunori Iwade
Journal:  Clin Case Rep       Date:  2016-10-11

4.  Intermittent failure of pacing output caused by algorithm to prevent T-wave oversensing.

Authors:  Imre Hunyor; Hany S Abed; Raymond W Sy; Emily C Hodkinson; Peter Santucci; Mark A McGuire
Journal:  HeartRhythm Case Rep       Date:  2016-03-31

5.  An unusual cause for inappropriate defibrillator shock.

Authors:  Debabrata Bera; Antareep Halder; Biswajit Majumder; Arup Kumar Ghosh; Debdatta Bhattacharyya
Journal:  Indian Pacing Electrophysiol J       Date:  2022-07-21
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.