Elekta Precise Table characteristics of IGRT remote table positioning.

Hans L Riis1, Sune J Zimmermann.   

Abstract

INTRODUCTION: Cone beam CT is a powerful tool to ensure an optimum patient positioning in radiotherapy. When cone beam CT scan of a patient is acquired, scan data of the patient are compared and evaluated against a reference image set and patient position offset is calculated. Via the linac control system, the patient is moved to correct for position offset and treatment starts. This procedure requires a reliable system for movement of patient. In this work we present a new method to characterize the reproducibility, linearity and accuracy in table positioning. The method applies to all treatment tables used in radiotherapy.
MATERIAL AND METHODS: The table characteristics are investigated on our two recent Elekta Synergy Platforms equipped with Precise Table installed in a shallow pit concrete cavity. Remote positioning of the table uses the auto set-up (ASU) feature in the linac control system software Desktop Pro R6.1. The ASU is used clinically to correct for patient positioning offset calculated via cone beam CT (XVI)-software. High precision steel rulers and a USB-microscope has been used to detect the relative table position in vertical, lateral and longitudinal direction. The effect of patient is simulated by applying external load on the iBEAM table top. For each table position an image is exposed of the ruler and display values of actual table position in the linac control system is read out. The table is moved in full range in lateral direction (50 cm) and longitudinal direction (100 cm) while in vertical direction a limited range is used (40 cm). RESULTS AND DISCUSSION: Our results show a linear relation between linac control system read out and measured position. Effects of imperfect calibration are seen. A reproducibility within a standard deviation of 0.22 mm in lateral and longitudinal directions while within 0.43 mm in vertical direction has been observed. The usage of XVI requires knowledge of the characteristics of remote table positioning. It is our opinion that the method presented meets the requirements in high precision IGRT.

Entities:  

Mesh:

Year:  2009        PMID: 18756401     DOI: 10.1080/02841860802311007

Source DB:  PubMed          Journal:  Acta Oncol        ISSN: 0284-186X            Impact factor:   4.089


  4 in total

1.  Efficient and accurate stereotactic radiotherapy using flattening filter free beams and HexaPOD robotic tables.

Authors:  Morten Nielsen; Christian R Hansen; Carsten Brink; Anders S Bertelsen; Charlotte Kristiansen; Jeppesen Stefan S; Olfred Hansen
Journal:  J Radiosurg SBRT       Date:  2016

2.  Automated algorithm for calculation of setup corrections and planning target volume margins for offline image-guided radiotherapy protocols.

Authors:  Auwal Abubakar; Nada Alia M Zamri; Shazril Imran Shaukat; Hafiz Mohd Zin
Journal:  J Appl Clin Med Phys       Date:  2021-06-09       Impact factor: 2.102

3.  Effect of the simulated half leaf width of a multileaf collimator on volumetric modulated arc therapy plan quality in hippocampal avoidance whole-brain radiotherapy.

Authors:  Ming-Hsien Li; Li-Jhen Chen; Chih-Chieh Chang; Jo-Ting Tsai; Jang-Chun Lin
Journal:  J Appl Clin Med Phys       Date:  2022-03-03       Impact factor: 2.243

4.  Improved accuracy for noncoplanar radiotherapy: an EPID-based method for submillimeter alignment of linear accelerator table rotation with MV isocenter.

Authors:  Matthew J Nyflot; Ning Cao; Juergen Meyer; Eric C Ford
Journal:  J Appl Clin Med Phys       Date:  2014-03-06       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.