L H Ooi1, N N Lo, S J Yeo, B C Ong, Z P Ding, A Lefi. 1. Department of Orthopaedic Surgery, Tan Tock Seng Hospital, 11 Jalan Tan Tock Seng, Singapore 308433. lai_hock_ooi@ttsh.com.sg
Abstract
INTRODUCTION: The study aims to show that total knee arthroplasty using computer-assisted surgical navigation without intramedullary rodding is safer than conventional intramedullary techniques in preventing venous thromboembolism. METHODS: 30 patients were grouped into groups of 10. Groups A and B had conventional intramedullary rodding of the femur and/or tibia. Group C had no rodding of the femur and tibia using computer-assisted surgical navigation. The degree, duration and size of the embolic shower were captured by a transoesophageal echocardiography probe. The echogenic emboli were graded according to the Mayo Clinic score. Haemodynamic parameters such as pulse oximetry oxygen saturation, end-tidal carbon dioxide, heart rate and mean arterial pressure were also recorded. RESULTS: There was a significant difference in the size of the emboli and the Mayo Clinic score when comparing the groups with intramedullary rodding and those without. There was also a significant difference in the pulse oximetry oxygen saturation and heart rate when the group without intramedullary rodding was compared with groups with rodding. CONCLUSION: Surgical navigation total knee arthroplasty may be safer than conventional total knee replacement with intramedullary rodding in preventing venous thromboembolism.
INTRODUCTION: The study aims to show that total knee arthroplasty using computer-assisted surgical navigation without intramedullary rodding is safer than conventional intramedullary techniques in preventing venous thromboembolism. METHODS: 30 patients were grouped into groups of 10. Groups A and B had conventional intramedullary rodding of the femur and/or tibia. Group C had no rodding of the femur and tibia using computer-assisted surgical navigation. The degree, duration and size of the embolic shower were captured by a transoesophageal echocardiography probe. The echogenic emboli were graded according to the Mayo Clinic score. Haemodynamic parameters such as pulse oximetry oxygen saturation, end-tidal carbon dioxide, heart rate and mean arterial pressure were also recorded. RESULTS: There was a significant difference in the size of the emboli and the Mayo Clinic score when comparing the groups with intramedullary rodding and those without. There was also a significant difference in the pulse oximetry oxygen saturation and heart rate when the group without intramedullary rodding was compared with groups with rodding. CONCLUSION: Surgical navigation total knee arthroplasty may be safer than conventional total knee replacement with intramedullary rodding in preventing venous thromboembolism.
Authors: Alberto Carli; Ahmed Aoude; Avishai Reuven; Bogdan Matache; John Antoniou; David J Zukor Journal: Can J Surg Date: 2014-10 Impact factor: 2.089