Literature DB >> 18755579

Au-nanoparticles as an electrochemical sensing platform for aptamer-thrombin interaction.

Elena Suprun1, Victoria Shumyantseva, Tatiana Bulko, Svetlana Rachmetova, Sergei Rad'ko, Nikolay Bodoev, Alexander Archakov.   

Abstract

A novel electrochemical method for the detection of bioaffinity interactions based on a gold-nanoparticles sensing platform and on the usage of stripping voltammetry technique was developed. The oxidation of gold surface (resulted in gold oxide formation) upon polarization served as a basis for analytical response. As a model, thrombin-thrombin binding aptamer couple was chosen. The aptamer was immobilized on a screen-printed electrode modified with gold-nanoparticles by avidin-biotin technology. Cathodic peak area was found proportional to thrombin quantity specifically adsorbed onto electrode surface. Sigmoid calibration curve as is typical for immunoassay was obtained, with thrombin detection limit of 10(-9)M. Linear range corresponds from 10(-8) to 10(-5)M thrombin concentration or 2 x 10(-14) to 2 x 10(-11)mol/electrode (R=0.996). Binding of thrombin to an aptamer has also been detected using the ferricyanide/ferrocyanide redox couple as electrochemical indicator.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18755579     DOI: 10.1016/j.bios.2008.07.008

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  3-D printed microfluidics for rapid prototyping and testing of electrochemical, aptamer-based sensor devices under flow conditions.

Authors:  Israel Belmonte; Ryan J White
Journal:  Anal Chim Acta       Date:  2021-12-17       Impact factor: 6.558

Review 2.  Noble metal nanoparticles for biosensing applications.

Authors:  Gonçalo Doria; João Conde; Bruno Veigas; Leticia Giestas; Carina Almeida; Maria Assunção; João Rosa; Pedro V Baptista
Journal:  Sensors (Basel)       Date:  2012-02-07       Impact factor: 3.576

Review 3.  Electrochemical and AFM Characterization of G-Quadruplex Electrochemical Biosensors and Applications.

Authors:  Ana-Maria Chiorcea-Paquim; Ramon Eritja; Ana Maria Oliveira-Brett
Journal:  J Nucleic Acids       Date:  2018-01-31

Review 4.  Technology Advancements in Blood Coagulation Measurements for Point-of-Care Diagnostic Testing.

Authors:  Mohammad Mohammadi Aria; Ahmet Erten; Ozlem Yalcin
Journal:  Front Bioeng Biotechnol       Date:  2019-12-11
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.