Literature DB >> 18755557

Breast-conserving therapy: radiotherapy margins for breast tumor bed boost.

Rajko Topolnjak1, Corine van Vliet-Vroegindeweij, Jan-Jakob Sonke, Danny Minkema, Peter Remeijer, Jasper Nijkamp, Paula Elkhuizen, Coen Rasch.   

Abstract

PURPOSE: To quantify the interfraction position variability of the excision cavity (EC) and to compare the rib and breast surface as surrogates for the cavity. Additionally, we sought to determine the required margin for on-line, off-line and no correction protocols in external beam radiotherapy. METHODS AND MATERIALS: A total of 20 patients were studied who had been treated in the supine position for 28 daily fractions. Cone-beam computed tomography scans were regularly acquired according to a shrinking action level setup correction protocol based on bony anatomy registration of the ribs and sternum. The position of the excision area was retrospectively analyzed by gray value cone-beam computed tomography-to-computed tomography registration. Subsequently, three setup correction strategies (on-line, off-line, and no corrections) were applied, according to the rib and breast surface registrations, to estimate the residual setup errors (systematic [Sigma] and random [sigma]) of the excision area. The required margins were calculated using a margin recipe.
RESULTS: The image quality of the cone-beam computed tomography scans was sufficient for localization of the EC. The margins required for the investigated setup correction protocols and the setup errors for the left-right, craniocaudal and anteroposterior directions were 8.3 mm (Sigma = 3.0, sigma = 2.6), 10.6 mm (Sigma = 3.8, sigma = 3.2), and 7.7 mm (Sigma = 2.7, sigma = 2.9) for the no correction strategy; 5.6 mm (Sigma = 2.0, Sigma = 1.8), 6.5 mm (Sigma = 2.3, sigma = 2.3), and 4.5 mm (Sigma = 1.5, sigma = 1.9) for the on-line rib strategy; and 5.1 mm (Sigma = 1.8, sigma = 1.7), 4.8 mm (Sigma = 1.7, sigma = 1.6), and 3.3 mm (Sigma = 1.1, sigma = 1.6) for the on-line surface strategy, respectively.
CONCLUSION: Considerable geometric uncertainties in the position of the EC relative to the bony anatomy and breast surface have been observed. By using registration of the breast surface, instead of the rib, the uncertainties in the position of the EC area were reduced.

Entities:  

Mesh:

Year:  2008        PMID: 18755557     DOI: 10.1016/j.ijrobp.2008.06.1924

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  7 in total

1.  Set-up uncertainty during breast radiotherapy. Image-guided radiotherapy for patients with initial extensive variation.

Authors:  D S Yang; W S Yoon; S Y Chung; J A Lee; S Lee; Y J Park; C Y Kim; G S Son
Journal:  Strahlenther Onkol       Date:  2013-02-28       Impact factor: 3.621

2.  Impact of residual and intrafractional errors on strategy of correction for image-guided accelerated partial breast irradiation.

Authors:  Gang Cai; Wei-Gang Hu; Jia-Yi Chen; Xiao-Li Yu; Zi-Qiang Pan; Zhao-Zhi Yang; Xiao-Mao Guo; Zhi-Min Shao; Guo-Liang Jiang
Journal:  Radiat Oncol       Date:  2010-10-26       Impact factor: 3.481

3.  Comparison of setup accuracy of three different image assessment methods for tangential breast radiotherapy.

Authors:  Vikneswary Batumalai; Penny Phan; Callie Choong; Lois Holloway; Geoff P Delaney
Journal:  J Med Radiat Sci       Date:  2016-05-31

4.  Setup Error Assessment and Correction in Planar kV Image- Versus Cone Beam CT Image-Guided Radiation Therapy: A Clinical Study of Early Breast Cancer Treated With External Beam Partial Breast Irradiation.

Authors:  Wei Wang; Ting Yu; Min Xu; Qian Shao; Yingjie Zhang; Jianbin Li
Journal:  Technol Cancer Res Treat       Date:  2019 Jan-Dec

5.  Evaluation of dosimetric variance in whole breast forward-planned intensity-modulated radiotherapy based on 4DCT and 3DCT.

Authors:  Wei Wang; Jian Bin Li; Hong Guang Hu; Tao Sun; Min Xu; Ting Yong Fan; Qian Shao
Journal:  J Radiat Res       Date:  2013-01-24       Impact factor: 2.724

6.  An imaging evaluation of the simultaneously integrated boost breast radiotherapy technique.

Authors:  Jessica Turley; Elizabeth Claridge Mackonis
Journal:  J Med Radiat Sci       Date:  2015-08-21

7.  A multicentre study of the evidence for customized margins in photon breast boost radiotherapy.

Authors:  Emma J Harris; Mukesh B Mukesh; Ellen M Donovan; Anna M Kirby; Joanne S Haviland; Raj Jena; John Yarnold; Angela Baker; June Dean; Sally Eagle; Helen Mayles; Claire Griffin; Rosalind Perry; Andrew Poynter; Charlotte E Coles; Philip M Evans
Journal:  Br J Radiol       Date:  2015-11-20       Impact factor: 3.039

  7 in total