Literature DB >> 18753818

Adenosine stress rubidium-82 PET/computed tomography in patients with known and suspected coronary artery disease.

Fabio P Esteves1, Rupan Sanyal, Jonathon A Nye, Cesar A Santana, Liudmila Verdes, Paolo Raggi.   

Abstract

BACKGROUND: Integrated positron emission tomography/computed tomography (PET/CT) is increasingly being utilized for myocardial perfusion imaging (MPI). However, there is a potential for increased imaging artifact compared with standard PET due to the different temporal resolution of PET and CT. We reviewed the diagnostic accuracy of adenosine stress Rb myocardial perfusion PET/CT to detect obstructive coronary artery disease (CAD) on invasive angiography at our institution. METHODS AND
RESULTS: Seventy-five patients were included, 23 (13 men, mean age 55.8+/-11.8 years) with low likelihood of CAD and 52 (28 men, mean age 67.1+/-11.4 years) with intermediate to high pretest probability of disease. Coronary angiography was performed only in the latter 52 patients on average within 17 days of the MPI study. The test characteristics of PET/CT MPI were assessed using a threshold of >or=50 and >or=70% stenosis in one or more major coronary artery on invasive angiography. Dedicated software was used for registration, processing, and interpretation. Consensus interpretation of the tomographic PET slices using a 4-point scale (1=definitely normal, 2=probably normal, 3=probably abnormal, 4=definitely abnormal) was done by two readers blinded to clinical information.
RESULTS: All MPI studies in the 23 low likelihood patients were normal. In the remaining 52 patients using a stenosis severity>or=50%, global sensitivity and specificity, negative and positive predictive value for detection of CAD were 86, 100, 57, and 100%. Using a stenosis severity>or=70%, these values changed to 90, 83, 71, and 87%.
CONCLUSION: Adenosine stress Rb MPI using PET/CT with manual registration demonstrates diagnostic accuracy comparable with that of traditional PET MPI.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18753818     DOI: 10.1097/MNM.0b013e328301a614

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  6 in total

Review 1.  Current state of hybrid imaging: attenuation correction and fusion.

Authors:  Jonathon A Nye; Tracy L Faber
Journal:  J Nucl Cardiol       Date:  2011-05-07       Impact factor: 5.952

2.  Prompt-gamma compensation in Rb-82 myocardial perfusion 3D PET/CT.

Authors:  Fabio P Esteves; Jonathan A Nye; Akbar Khan; Russell D Folks; Raghuveer K Halkar; Ernest V Garcia; David M Schuster; Stamatios Lerakis; Paolo Raggi; John R Votaw
Journal:  J Nucl Cardiol       Date:  2009-11-24       Impact factor: 5.952

Review 3.  Calcification in atherosclerosis.

Authors:  Nikolaos Alexopoulos; Paolo Raggi
Journal:  Nat Rev Cardiol       Date:  2009-09-29       Impact factor: 32.419

Review 4.  Diagnosing coronary artery disease with hybrid PET/CT: it takes two to tango.

Authors:  Ibrahim Danad; Pieter G Raijmakers; Paul Knaapen
Journal:  J Nucl Cardiol       Date:  2013-10       Impact factor: 5.952

5.  Protective effects of fufang xueshuantong on diabetic retinopathy in rats.

Authors:  Huihui Duan; Jianmei Huang; Wei Li; Minke Tang
Journal:  Evid Based Complement Alternat Med       Date:  2013-09-24       Impact factor: 2.629

6.  Nicotine exposure exacerbates development of cataracts in a type 1 diabetic rat model.

Authors:  Nima Tirgan; Gabriela A Kulp; Praveena Gupta; Adam Boretsky; Tomasz A Wiraszka; Bernard Godley; Ronald G Tilton; Massoud Motamedi
Journal:  Exp Diabetes Res       Date:  2012-09-20
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.