Literature DB >> 18752515

Heidelberg retina tomograph parameters of the optic disc in eyes with progressive retinal nerve fibre layer defects.

Ville Saarela1, P Juhani Airaksinen.   

Abstract

PURPOSE: To determine the Heidelberg retina tomograph (HRT) parameters that identify glaucomatous changes in optic nerve head (ONH) topography associated with progression of retinal nerve fibre layer (RNFL) defects.
METHODS: A total of 68 eyes with open-angle glaucoma were included in this retrospective study: 34 eyes showed progression of an RNFL defect during the follow-up period and 34 eyes did not. Successful RNFL photographs and scanning laser tomography examinations with the HRT were taken in all patients at each of three visits. The change in HRT parameter values during follow-up was calculated.
RESULTS: Progression of the RNFL defect was statistically significantly correlated (p = 0.049) with only one topographic ONH parameter, the cup shape measure. The best combination of two parameters (p = 0.009) included the maximum cup depth and the linear cup : disc area ratio; the best combination of three parameters (p = 0.007) included the maximum cup depth, the linear cup : disc area ratio and the horizontal cup : disc area ratio. Sensitivity and specificity values were 52.9% and 73.5%, respectively, for the cup shape measure, 70.6% and 73.5%, respectively, for the two-parameter combination, and 76.5% and 79.4%, respectively, for the three-parameter combination. The areas under the receiver operating characteristic curve were 0.617, 0.724 and 0.753, respectively.
CONCLUSIONS: The results indicate that the HRT parameters may be used to detect small ONH changes associated with progression of the RNFL defect. With the exception of the cup shape measure, the parameters which provide the best correlation with progression differ from those considered optimal for recognizing the presence or absence of glaucoma.

Entities:  

Mesh:

Year:  2008        PMID: 18752515     DOI: 10.1111/j.1600-0420.2007.01119.x

Source DB:  PubMed          Journal:  Acta Ophthalmol        ISSN: 1755-375X            Impact factor:   3.761


  5 in total

1.  Correlations between corneal and optic nerve head variables in healthy subjects and patients with primary open angle glaucoma.

Authors:  Federico Saenz-Frances; Luis Jañez; Lara Borrego-Sanz; Clara Berrozpe-Villabona; Jose Maria Martinez-de-la-Casa; Laura Morales-Fernandez; Julian Garcia-Sanchez; Enrique Santos-Bueso; Julian Garcia-Feijoo
Journal:  Int J Ophthalmol       Date:  2015-12-18       Impact factor: 1.779

2.  Characteristic correlations of the structure-function relationship in different glaucomatous disc types.

Authors:  Kazuko Omodaka; Naoko Takada; Takuhiro Yamaguchi; Hidetoshi Takahashi; Makoto Araie; Toru Nakazawa
Journal:  Jpn J Ophthalmol       Date:  2015-04-11       Impact factor: 2.447

Review 3.  Test-retest variability in structural parameters measured with glaucoma imaging devices.

Authors:  Makoto Araie
Journal:  Jpn J Ophthalmol       Date:  2012-11-09       Impact factor: 2.447

4.  Correlation between morphology of optic disc determined by Heidelberg Retina Tomograph II and visual function in eyes with open-angle glaucoma.

Authors:  Kazuko Omodaka; Toru Nakazawa; Takaaki Otomo; Masahiko Nakamura; Nobuo Fuse; Kohji Nishida
Journal:  Clin Ophthalmol       Date:  2010-07-30

5.  Association between optic nerve blood flow and objective examinations in glaucoma patients with generalized enlargement disc type.

Authors:  Naoki Chiba; Kazuko Omodaka; Yu Yokoyama; Naoko Aizawa; Satoru Tsuda; Masayuki Yasuda; Takaaki Otomo; Shunji Yokokura; Nobuo Fuse; Toru Nakazawa
Journal:  Clin Ophthalmol       Date:  2011-10-28