Literature DB >> 18752279

Knee stability before and after total and unicondylar knee replacement: in vivo kinematic evaluation utilizing navigation.

Daniela Casino1, Sandra Martelli, Stefano Zaffagnini, Nicola Lopomo, Francesco Iacono, Simone Bignozzi, Andrea Visani, Maurilio Marcacci.   

Abstract

Surgical navigation systems are currently used to guide the surgeon in the correct alignment of the implant. The aim of this study was to expand the use of navigation systems by proposing a surgical protocol for intraoperative kinematics evaluations during knee arthroplasty. The protocol was evaluated on 20 patients, half undergoing unicondylar knee arthroplasty (UKA) and half undergoing posterior-substituting, rotating-platform total knee arthroplasty (TKA). The protocol includes a simple acquisition procedure and an original elaboration methodology. Kinematic tests were performed before and after surgery and included varus/valgus stress at 0 and 30 degrees and passive range of motion. Both UKA and TKA improved varus/valgus stability in extension and preserved the total magnitude of screw-home motion during flexion. Moreover, compared to preoperative conditions, values assumed by tibial axial rotation during flexion in TKA knees were more similar to the rotating patterns of UKA knees. The analysis of the anteroposterior displacement of the knee compartments confirmed that the two prostheses did not produce medial pivoting, but achieved a postoperative normal behavior. These results demonstrated that proposed intraoperative kinematics evaluations by a navigation system provided new information on the functional outcome of the reconstruction useful to restore knee kinematics during surgery.

Entities:  

Mesh:

Year:  2009        PMID: 18752279     DOI: 10.1002/jor.20746

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  12 in total

1.  In vivo function of posterior cruciate ligament before and after posterior cruciate ligament-retaining total knee arthroplasty.

Authors:  Bing Yue; Kartik M Varadarajan; Harry E Rubash; Guoan Li
Journal:  Int Orthop       Date:  2012-01-25       Impact factor: 3.075

2.  Relationship between the tibial anteroposterior axis and the surgical epicondylar axis in varus and valgus knees.

Authors:  Shinya Kawahara; Shuichi Matsuda; Ken Okazaki; Yasutaka Tashiro; Hiroaki Mitsuyasu; Hiroyuki Nakahara; Yukihide Iwamoto
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-12-29       Impact factor: 4.342

3.  UKA closely preserves natural knee kinematics in vitro.

Authors:  Thomas J Heyse; Bilal F El-Zayat; Ronny De Corte; Yan Chevalier; Lennart Scheys; Bernardo Innocenti; Susanne Fuchs-Winkelmann; Luc Labey
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-11-09       Impact factor: 4.342

4.  Anteroposterior and rotational stability in fixed and mobile bearing unicondylar knee arthroplasty: a cadaveric study using the robotic force sensor system.

Authors:  Roland Becker; Christian Mauer; Christian Stärke; Mathias Brosz; Thore Zantop; Christoph H Lohmann; Martin Schulze
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-08-07       Impact factor: 4.342

5.  Comparing navigation-based in vivo knee kinematics pre- and postoperatively between a cruciate-retaining and a cruciate-substituting implant.

Authors:  Clemens Baier; Hans-Robert Springorum; Jürgen Götz; Jens Schaumburger; Christian Lüring; Joachim Grifka; Johannes Beckmann
Journal:  Int Orthop       Date:  2013-01-30       Impact factor: 3.075

6.  Is there a gold standard for TKA tibial component rotational alignment?

Authors:  Erin E Hutter; Jeffrey F Granger; Matthew D Beal; Robert A Siston
Journal:  Clin Orthop Relat Res       Date:  2013-02-08       Impact factor: 4.176

7.  Correlation between preoperative and postoperative knee kinematics in total knee arthroplasty using cruciate retaining designs.

Authors:  Jong Keun Seon; Ju Kwon Park; Mun Su Jeong; Woo Bin Jung; Kyung Soon Park; Taek Rim Yoon; Eun Kyoo Song
Journal:  Int Orthop       Date:  2010-04-30       Impact factor: 3.075

8.  Deep-dished highly congruent tibial insert in CR-TKA does not prevent patellar tendon angle increase and patellar anterior translation.

Authors:  Ibrahim Akkawi; Francesca Colle; Danilo Bruni; Giovanni Francesco Raspugli; Simone Bignozzi; Stefano Zaffagnini; Francesco Iacono; Maurilio Marcacci
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-02-12       Impact factor: 4.342

9.  Kinematic factors affecting postoperative knee flexion after cruciate-retaining total knee arthroplasty.

Authors:  Tokio Matsuzaki; Tomoyuki Matsumoto; Hirotsugu Muratsu; Seiji Kubo; Takehiko Matsushita; Yohei Kawakami; Kazunari Ishida; Shinya Oka; Ryosuke Kuroda; Masahiro Kurosaka
Journal:  Int Orthop       Date:  2013-03-05       Impact factor: 3.075

10.  Comparison of outcomes after bilateral simultaneous total knee arthroplasty using posterior-substituting versus cruciate-retaining prostheses.

Authors:  Hong-Guang Liu; Wei Zhu; Zhen-Xiang Zhang
Journal:  Saudi Med J       Date:  2015-02       Impact factor: 1.484

View more