Literature DB >> 1874917

Assay of anti-HBs antibodies using a recombinant antigen and latex particle counting: comparison with five commercial tests.

L M Galanti1, C Cornu, P L Masson, A R Robert, D Becheanu, M E Lamy, C L Cambiaso.   

Abstract

An assay of anti-HBs antibodies based on agglutination of latex particles coated with recombinant HBs-antigen was compared with Abbott radioimmunoassay (Abbott-RIA), which uses a human plasma-derived antigen. The population examined consisted of 76 Abbott-RIA anti-HBs-negative prevaccinated subjects and 1044 serum samples anti-HBs found positive by Abbott-RIA, including 283 samples of subjects vaccinated either with a human plasma-derived vaccine (group A; n = 180) or with a recombinant vaccine (group B; n = 103). Correlation coefficients between the two techniques were respectively r = 0.89 for the whole population (n = 1044), r = 0.98 in group A and r = 0.74 in group B. Anti-HBs titres were higher with latex than with RIA in group B as shown by the regression slopes: latex = 508 + 1.11 RIA in group A and latex = -1138 + 3.97 RIA in group B, suggesting that some vaccinated subjects from group B produced antibodies against epitopes proper to the recombinant antigen. In the prevaccinated population and in group A, the latex results were compared with those of radioimmunoassays (Abbott, Sorin) and enzyme immunoassays (Behring, Roche, Pasteur). Only the Roche-EIA detected anti-HBs in the prevaccinated subjects. The correlation between the various immunoassays was r greater than 0.96 only for values higher than 100 IU/l.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1874917     DOI: 10.1016/0166-0934(91)90053-3

Source DB:  PubMed          Journal:  J Virol Methods        ISSN: 0166-0934            Impact factor:   2.014


  2 in total

1.  Comparison of nine commercially available assays for quantification of antibody response to hepatitis B virus surface antigen.

Authors:  D Huzly; T Schenk; W Jilg; D Neumann-Haefelin
Journal:  J Clin Microbiol       Date:  2008-02-06       Impact factor: 5.948

2.  Whole-blood counting immunoassay as a short-turnaround test for detection of hepatitis B surface antigen, anti-hepatitis C virus antibodies, and anti-Treponema pallidum antibodies.

Authors:  Toyoichiro Kudo; Aiko Kido; Yukiko Nishiyama; Hiroshi Koganeya; Takako Okuda; Motoshige Nabeshima; Yoshitsugu Iinuma; Satoshi Ichiyama
Journal:  J Clin Microbiol       Date:  2004-09       Impact factor: 5.948

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.