Literature DB >> 18729474

Interactions between multiple cell types in parallel microfluidic channels: monitoring platelet adhesion to an endothelium in the presence of an anti-adhesion drug.

Chia-Jui Ku1, Teresa D'Amico Oblak, Dana M Spence.   

Abstract

A simple method for immobilizing endothelial cells in the channels of a microfluidic device fabricated with soft lithography is presented that requires no surface oxidation of the substrate material used in conjunction with the microfluidic device and is operable even with a reversible seal. Specifically, optimal conditions for culturing bovine pulmonary artery endothelial cells (bPAECs) to the surface of a Petri dish were investigated. The parameters investigated included fibronectin concentration, temperature, seeding density, and immobilization time. To enhance the utility of the device, all optimization studies, and studies involving platelet adhesion to the immobilized endothelium, were performed in parallel channels, thereby enabling improved throughput over a single channel device. The optimal conditions for cell immobilization included coating the Petri dish with 100 microg/mL fibronectin, a seeding cell density of 1.00 x 10(5) cells mL(-1), and an immobilization time of 90 min at 37 degrees C. The device was then employed to monitor the physical interaction (adhesion) of platelets to the immobilized endothelium in the presence of a known platelet activator (ADP) and a drug inhibitor of platelet activation. The number of platelets adhering to the endothelial cells in the channels increased from 17.0 +/- 2.3 in the absence of ADP to 63.2 +/- 2.4 in the presence of 5.00 microM ADP. Moreover, the data presented here also shows that inhibition of endothelium nitric oxide (NO) production, a recognized inhibitor of platelet adhesion to the endothelium, increased the number of platelets adhering to the surface to 35.4 +/- 1.0. In the presence of NO inhibition and 5.00 microM ADP, the affect on platelet adhesion was further increased to 127 +/- 5.2. Finally, this device was employed to investigate the effect of a drug known to inhibit platelet adhesion (clopidogrel) and, in the presence of the drug, the platelet adhesion due to activation by 5.00 microM ADP decreased to 24.0 +/- 3.8. This work is the first representation of multiple cell types physically interacting in the channels of a microfluidic device and further demonstrates the potential of these devices in the drug discovery process and drug efficacy studies.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18729474      PMCID: PMC2779699          DOI: 10.1021/ac801114j

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  29 in total

1.  A membrane-based microfluidic device for controlling the flux of platelet agonists into flowing blood.

Authors:  Keith B Neeves; Scott L Diamond
Journal:  Lab Chip       Date:  2008-04-03       Impact factor: 6.799

Review 2.  Nitric oxide in the vasculature: physiology and pathophysiology.

Authors:  S Moncada
Journal:  Ann N Y Acad Sci       Date:  1997-04-15       Impact factor: 5.691

3.  Extracellular ATP signaling in the rabbit lung: erythrocytes as determinants of vascular resistance.

Authors:  Randy S Sprague; Jeffrey J Olearczyk; Dana M Spence; Alan H Stephenson; Robert W Sprung; Andrew J Lonigro
Journal:  Am J Physiol Heart Circ Physiol       Date:  2003-04-10       Impact factor: 4.733

4.  Fluorescence monitoring of ATP-stimulated, endothelium-derived nitric oxide production in channels of a poly(dimethylsiloxane)-based microfluidic device.

Authors:  Teresa D'Amico Oblak; Paul Root; Dana M Spence
Journal:  Anal Chem       Date:  2006-05-01       Impact factor: 6.986

5.  EDRF generation and release from perfused bovine pulmonary artery and vein.

Authors:  L J Ignarro; G M Buga; G Chaudhuri
Journal:  Eur J Pharmacol       Date:  1988-04-27       Impact factor: 4.432

6.  Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane).

Authors:  D C Duffy; J C McDonald; O J Schueller; G M Whitesides
Journal:  Anal Chem       Date:  1998-12-01       Impact factor: 6.986

7.  Nitric oxide released from activated platelets inhibits platelet recruitment.

Authors:  J E Freedman; J Loscalzo; M R Barnard; C Alpert; J F Keaney; A D Michelson
Journal:  J Clin Invest       Date:  1997-07-15       Impact factor: 14.808

8.  The effects of pentoxifylline on diabetic renal changes in streptozotocin-induced diabetes mellitus.

Authors:  Zubeyde Gunduz; Ozlem Canoz; Huseyin Per; Ruhan Dusunsel; M Hakan Poyrazoglu; Coskun Tez; Recep Saraymen
Journal:  Ren Fail       Date:  2004-11       Impact factor: 2.606

9.  Release of ATP from human erythrocytes in response to a brief period of hypoxia and hypercapnia.

Authors:  G R Bergfeld; T Forrester
Journal:  Cardiovasc Res       Date:  1992-01       Impact factor: 10.787

10.  Metal-activated C-peptide facilitates glucose clearance and the release of a nitric oxide stimulus via the GLUT1 transporter.

Authors:  J A Meyer; J M Froelich; G E Reid; W K A Karunarathne; D M Spence
Journal:  Diabetologia       Date:  2007-10-27       Impact factor: 10.122

View more
  13 in total

1.  Integrated hybrid polystyrene-polydimethylsiloxane device for monitoring cellular release with microchip electrophoresis and electrochemical detection.

Authors:  Alicia S Johnson; Benjamin T Mehl; R Scott Martin
Journal:  Anal Methods       Date:  2015-02-07       Impact factor: 2.896

2.  P2Y12 or P2Y1 inhibitors reduce platelet deposition in a microfluidic model of thrombosis while apyrase lacks efficacy under flow conditions.

Authors:  S F Maloney; Lawrence F Brass; S L Diamond
Journal:  Integr Biol (Camb)       Date:  2010-01-05       Impact factor: 2.192

3.  Microfluidics as a functional tool for cell mechanics.

Authors:  Siva A Vanapalli; Michel H G Duits; Frieder Mugele
Journal:  Biomicrofluidics       Date:  2009-01-05       Impact factor: 2.800

4.  Elastomeric microposts integrated into microfluidics for flow-mediated endothelial mechanotransduction analysis.

Authors:  Raymond H W Lam; Yubing Sun; Weiqiang Chen; Jianping Fu
Journal:  Lab Chip       Date:  2012-03-21       Impact factor: 6.799

5.  On-chip evaluation of shear stress effect on cytotoxicity of mesoporous silica nanoparticles.

Authors:  Donghyuk Kim; Yu-Shen Lin; Christy L Haynes
Journal:  Anal Chem       Date:  2011-10-27       Impact factor: 6.986

6.  Rapid prototyping of arrayed microfluidic systems in polystyrene for cell-based assays.

Authors:  Edmond W K Young; Erwin Berthier; David J Guckenberger; Eric Sackmann; Casey Lamers; Ivar Meyvantsson; Anna Huttenlocher; David J Beebe
Journal:  Anal Chem       Date:  2011-01-24       Impact factor: 6.986

Review 7.  Microvascular platforms for the study of platelet-vessel wall interactions.

Authors:  Ying Zheng; Junmei Chen; José A López
Journal:  Thromb Res       Date:  2014-01-07       Impact factor: 3.944

8.  An easy to assemble microfluidic perfusion device with a magnetic clamp.

Authors:  Eugene Tkachenko; Edgar Gutierrez; Mark H Ginsberg; Alex Groisman
Journal:  Lab Chip       Date:  2009-02-06       Impact factor: 6.799

Review 9.  Microchip-based electrochemical detection for monitoring cellular systems.

Authors:  Alicia S Johnson; Asmira Selimovic; R Scott Martin
Journal:  Anal Bioanal Chem       Date:  2013-01-23       Impact factor: 4.142

Review 10.  Microfluidic technology in vascular research.

Authors:  A D van der Meer; A A Poot; M H G Duits; J Feijen; I Vermes
Journal:  J Biomed Biotechnol       Date:  2009-11-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.