Literature DB >> 18728903

Metal release rate from AISI 316L stainless steel and pure Fe, Cr and Ni into a synthetic biological medium--a comparison.

G Herting1, I Odnevall Wallinder, C Leygraf.   

Abstract

Metal release rates from stainless steel grade 316L were investigated in artificial lysosomal fluid (ALF), simulating a human inflammatory cell response. The main focus was placed on release rates of main alloying elements using graphite furnace atomic absorption spectroscopy, and changes in surface oxide composition by means of X-ray photoelectron spectroscopy. To emphasise that alloys and pure metals possess totally different intrinsic properties, comparative studies were performed on the pure alloying constituents: iron, nickel and chromium. Significant differences in release rates were observed due to the presence of a passive surface film on stainless steel. Iron and nickel were released at rates more than 300 times lower from the 316L alloy compared with the pure metals whereas the release rate of chromium was similar. Iron was preferentially released compared with nickel and chromium. Immersion in ALF resulted in the gradual enrichment of chromium in the surface film, a small increase of nickel, and the reduction of oxidized iron with decreasing release rates of alloy constituents as a result. As expected, released metals from stainless steel grade 316L were neither in proportion to the bulk alloy composition nor to the surface film composition.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18728903     DOI: 10.1039/b805075a

Source DB:  PubMed          Journal:  J Environ Monit        ISSN: 1464-0325


  8 in total

Review 1.  The biological response to orthopaedic implants for joint replacement: Part I: Metals.

Authors:  Emmanuel Gibon; Derek F Amanatullah; Florence Loi; Jukka Pajarinen; Akira Nabeshima; Zhenyu Yao; Moussa Hamadouche; Stuart B Goodman
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2016-06-21       Impact factor: 3.368

Review 2.  Nickel-free austenitic stainless steels for medical applications.

Authors:  Ke Yang; Yibin Ren
Journal:  Sci Technol Adv Mater       Date:  2010-02-26       Impact factor: 8.090

3.  Bioaccessibility of metals in alloys: evaluation of three surrogate biofluids.

Authors:  Wendy E Hillwalker; Kim A Anderson
Journal:  Environ Pollut       Date:  2013-11-08       Impact factor: 8.071

4.  Bioaccessibility, bioavailability and toxicity of commercially relevant iron- and chromium-based particles: in vitro studies with an inhalation perspective.

Authors:  Yolanda Hedberg; Johanna Gustafsson; Hanna L Karlsson; Lennart Möller; Inger Odnevall Wallinder
Journal:  Part Fibre Toxicol       Date:  2010-09-03       Impact factor: 9.400

5.  Surface-protein interactions on different stainless steel grades: effects of protein adsorption, surface changes and metal release.

Authors:  Y Hedberg; X Wang; J Hedberg; M Lundin; E Blomberg; I Odnevall Wallinder
Journal:  J Mater Sci Mater Med       Date:  2013-02-02       Impact factor: 3.896

6.  Biological behaviour of human umbilical artery smooth muscle cell grown on nickel-free and nickel-containing stainless steel for stent implantation.

Authors:  Liming Li; Liwen An; Xiaohang Zhou; Shuang Pan; Xin Meng; Yibin Ren; Ke Yang; Yifu Guan
Journal:  Sci Rep       Date:  2016-01-04       Impact factor: 4.379

7.  Microstructure, Mechanical, and Corrosion Properties of Ni-Free Austenitic Stainless Steel Prepared by Mechanical Alloying and HIPping.

Authors:  Eliza Romanczuk; Krzysztof Perkowski; Zbigniew Oksiuta
Journal:  Materials (Basel)       Date:  2019-10-18       Impact factor: 3.623

8.  Reduction of in-stent restenosis risk on nickel-free stainless steel by regulating cell apoptosis and cell cycle.

Authors:  Liming Li; Shuang Pan; Xiaohang Zhou; Xin Meng; Xiaoxi Han; Yibin Ren; Ke Yang; Yifu Guan
Journal:  PLoS One       Date:  2013-04-26       Impact factor: 3.240

  8 in total