Literature DB >> 18728610

Posterior reduction and fixation of an unstable Jefferson fracture with C1 lateral mass screws, C2 isthmus screws, and crosslink fixation: technical case report.

Enrico Tessitore1, Armen Momjian, Michael Payer.   

Abstract

OBJECTIVE: We sought to describe a modified technique for the reduction and stabilization of unstable Jefferson fractures. CLINICAL
PRESENTATION: We present the case of an isolated unstable Jefferson fracture in a 33-year-old woman. The patient was the victim of a motor vehicle accident. Her neurological examination was normal. A cervical computed tomographic scan revealed an isolated Jefferson fracture that we thought to be unstable when we applied the Spence criteria. TECHNIQUE: The fracture was treated by a technical variant of C1-C2 posterior fixation with compression on the rods by means of a crosslink connector, allowing the reduction of the atlantoaxial lateral mass overhanging. C1-C2 fusion with posterior iliac crest bone graft was added.
CONCLUSION: The 1-year radiological follow-up evaluation showed a complete consolidation of the fracture lines and atlantoaxial stability. This technique could be an option for the reduction and stabilization of the unstable Jefferson fractures.

Entities:  

Mesh:

Year:  2008        PMID: 18728610     DOI: 10.1227/01.neu.0000335022.91240.c9

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  4 in total

1.  A biomechanical rationale for C1-ring osteosynthesis as treatment for displaced Jefferson burst fractures with incompetency of the transverse atlantal ligament.

Authors:  Heiko Koller; Herbert Resch; Mark Tauber; Juliane Zenner; Peter Augat; Rainer Penzkofer; Frank Acosta; Klaus Kolb; Anton Kathrein; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2010-04-13       Impact factor: 3.134

2.  Comparison of occipitocervical and atlantoaxial fusion in treatment of unstable Jefferson fractures.

Authors:  Yong Hu; Zhen-Shan Yuan; Christopher K Kepler; Wei-Xin Dong; Xiao-Yang Sun; Jiao Zhang
Journal:  Indian J Orthop       Date:  2017 Jan-Feb       Impact factor: 1.251

3.  Computer-aided analysis for optimal screw insertion in lateral mass of C1: An anatomical study.

Authors:  Renate Krassnig; Jakob Andrea Orlandi; Ellen Tackner; Gloria Hohenberger; Paul Puchwein
Journal:  Arch Orthop Trauma Surg       Date:  2017-03-29       Impact factor: 3.067

4.  Posterior temporary fixation of C1-C2 screw-rod system for unstable C1 burst fracture.

Authors:  Yun-Lin Chen; Xu-Dong Hu; Yang Wang; Wei-Yu Jiang; Wei-Hu Ma
Journal:  Medicine (Baltimore)       Date:  2022-08-05       Impact factor: 1.817

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.