Literature DB >> 18727968

First report of a late type III endoleak from fabric tears of a Zenith stent graft.

Anders Wanhainen1, Rickard Nyman, Mats-Ola Eriksson, Martin Björck.   

Abstract

We report a case of a late type III endoleak from a hole in the fabric of the main body of a Zenith bifurcated endograft 7 years after implantation. Abdominal pain and a rapidly expanding aneurysm were eventually followed by rupture. The defect was detected at open surgery, whereas no evidence of endoleak was found at preoperative computed tomography (CT) or angiogram. The defect was repaired by a relining procedure with an Excluder stent graft. The patient, however, died 3 weeks after admission.

Entities:  

Mesh:

Year:  2008        PMID: 18727968     DOI: 10.1016/j.jvs.2008.03.047

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  12 in total

1.  Late type III endoleak from fabric tears of a zenith stent graft: report of a case.

Authors:  Hiroshi Banno; Hirofumi Morimae; Tsutomu Ihara; Masayoshi Kobayashi; Kiyohito Yamamoto; Kimihiro Komori
Journal:  Surg Today       Date:  2012-09-14       Impact factor: 2.549

2.  Endovascular Management of Type I Endoleak with Fenestrated Aortic "Cuff" and Afterwards Treatment of Endoleak Type III.

Authors:  Stevo Duvnjak
Journal:  Int J Angiol       Date:  2015-01-28

3.  Repair of a complex post-EVAR type III endoleak using a chimney aortouniiliac stent graft and femorofemoral crossover bypass.

Authors:  Jack Kian Ch'ng; Manish Taneja; Benjamin Soo Yeng Chua
Journal:  J Surg Case Rep       Date:  2013-04-23

4.  Type IIIb endoleak due to stent suture line fabric breakage in the Endurant stent graft: a case report.

Authors:  Satoshi Takahashi; Toshiya Nishibe; Masaki Kano; Shinobu Akiyama; Toru Iwahashi; Hitoshi Ogino
Journal:  Surg Case Rep       Date:  2022-04-19

5.  Delayed Type IIIb endoleak secondary to graft fabric tear 7 years following implantation of a Medtronic Talent endovascular aortic device: A case report and review of the literature.

Authors:  Vinay Kansal; Sudhir Nagpal
Journal:  SAGE Open Med Case Rep       Date:  2016-09-20

6.  Late Type 3b Endoleak Mimicking Type 2 Endoleak after Endovascular Aortic Aneurysm Repair.

Authors:  Minji Cho; Chanjoong Choi; Sungsin Cho; Song-Yi Kim; Sang-Il Min; Sanghyun Ahn; Jongwon Ha; Seung-Kee Min
Journal:  Vasc Specialist Int       Date:  2017-06-30

7.  Delayed Type III Endoleak Caused by Fabric Erosion after Endovascular Repair of an Abdominal Aortic Aneurysm.

Authors:  Jae Hang Lee; Eung-Joong Kim; Jin-Ho Choi
Journal:  Korean J Thorac Cardiovasc Surg       Date:  2017-08-05

8.  Endovascular Repair for a Ruptured AAA due to a Combined Type IIIb and Ia Endoleak.

Authors:  Konstantinos Ioannis Avgerinos; Nikolaos Melas; Athanasios Saratzis; Marianthi V Tympanidou; Nikolaos Saratzis; Ioannis Lazaridis
Journal:  Case Rep Vasc Med       Date:  2018-04-24

9.  Late Type 3b Endoleak with an Endurant Endograft.

Authors:  Mehmet Barburoglu; Bulent Acunas; Yilmaz Onal; Murat Ugurlucan; Omer Ali Sayin; Ufuk Alpagut
Journal:  Case Rep Radiol       Date:  2015-12-20

10.  Aneurysm sac enlargement 16 years after endovascular aortic aneurysm repair due to late type IIIb endoleak: A case report.

Authors:  Yuri Murakami; Naoki Toya; Soichiro Fukushima; Eisaku Ito; Tadashi Akiba; Takao Ohki
Journal:  Int J Surg Case Rep       Date:  2018-06-28
View more