| Literature DB >> 18727825 |
Antonio Piccoli1, PierGiorgio Crosignani, Carmine Nappi, Salvatore Ronsini, Vincenzina Bruni, Silvia Marelli.
Abstract
BACKGROUND: As weight gain is one of the most frequently cited reasons for not using and for discontinuing hormonal contraceptives, in an open-label, single-arm, multicentre clinical study we evaluated the effect of the ethinylestradiol/norelgestromin contraceptive patch (EVRA, Janssen-Cilag International, Belgium) on body composition using bioelectrical impedance analysis (BIA).Entities:
Mesh:
Substances:
Year: 2008 PMID: 18727825 PMCID: PMC2557005 DOI: 10.1186/1475-2891-7-21
Source DB: PubMed Journal: Nutr J ISSN: 1475-2891 Impact factor: 3.271
Distribution of body composition parameters over time
| Body weight, kg | R/H, Ohm/m | Xc/H, Ohm/m | TBW, L | ||||||
| Visit | n | M | SD | M | SD | M | SD | M | SD |
| Screening visit, T0 | 182 | 58.1 | 8.1 | 373.6 | 53.6 | 39.8 | 6.5 | 30.4 | 3.6 |
| After 1 month, T1 | 179 | 58.4 | 8.2 | 370.6 | 54.5 | 39.9 | 5.8 | 30.7 | 3.9 |
| After 3 months, T3 | 171 | 58.4 | 8.1 | 369.1 | 58.0 | 39.3 | 6.0 | 30.8 | 4.6 |
| After 6 months, T6 | 161 | 58.6 | 7.9 | 368.6 | 57.1 | 38.9 | 5.6 | 30.9 | 4.3 |
| T1-T0 | 179 | 0.26 | 1.34 | -1.92 | 25.7 | 0.22 | 5.1 | 0.19 | 1.49 |
| P(t) | 0.01 | ns | ns | ns | |||||
| T3-T0 | 171 | 0.42 | 1.76 | -4.89 | 30.7 | -0.51 | 5.5 | 0.49 | 2.40 |
| P(t) | 0.002 | 0.04 | ns | 0.008 | |||||
| T6-T0 | 161 | 0.64 | 1.94 | -6.11 | 31.2 | -1.11 | 6.5 | 0.51 | 2.07 |
| P(t) | <0.001 | 0.01 | 0.03 | 0.002 | |||||
T0, T1, T3, T6 = screening visit, after 1 month, 3 months, and 6 months
T1-T0, T3-T0, T6-T0 = change in parameters after 1 month, 3 months, and 6 months
t = Student's t test for paired data
Figure 1Impedance vector displacements after 1 month, 3 months and 6 months with their 95% confidence ellipses. Impedance vector displacements (arrows) after 1 month (T1-T0), 3 months (T3-T0) and after 6 months (T6-T0) with their 95% confidence ellipses. The vector displacement after 6 months is significantly different from zero (P < 0.05, 95% confidence ellipse not overlapping zero), due to a decrease in both components R/H and Xc/H. R is resistance, Xc reactance, H height, and d difference with respect to the screening visit T0.
Distribution of body composition parameters by previous contraceptive method
| Body weight, kg | R/H, Ohm/m | Xc/H, Ohm/m | TBW, L | ||||||
| Visit | n | M | SD | M | SD | M | SD | M | SD |
| T0/CM = 1 | 92 | 57.3 | 8.1 | 380.9 | 52.5 | 40.2 | 6.7 | 29.8 | 3.5 |
| T0/CM = 2 | 40 | 59.4 | 8.4 | 373.0 | 45.7 | 39.0 | 7.1 | 30.8 | 3.4 |
| T0/CM = 3 | 41 | 59.2 | 8.1 | 356.8 | 62.8 | 39.8 | 5.9 | 31.7 | 4.1 |
| P(ANOVA) | ns | ns | ns | 0.02 | |||||
| T1/CM = 1 | 89 | 57.8 | 8.2 | 376.4 | 51.5 | 40.6 | 5.7 | 30.1 | 3.8 |
| T1/CM = 2 | 40 | 59.2 | 8.4 | 373.4 | 47.0 | 39.5 | 6.4 | 30.8 | 3.5 |
| T1/CM = 3 | 41 | 59.4 | 8.0 | 354.8 | 67.5 | 39.5 | 5.4 | 32.0 | 4.6 |
| P(ANOVA) | ns | ns | ns | 0.04 | |||||
| T1-T0/CM = 1 | 89 | 0.40 | 1.42 | -2.48 | 26.6 | 0.50 | 5.4 | 0.21 | 1.58 |
| T1-T0/CM = 2 | 40 | -0.18 | 1.12 | 0.42 | 31.6 | 0.43 | 5.2 | -0.02 | 1.56 |
| T1-T0/CM = 3 | 41 | 0.28 | 1.19 | -2.06 | 19.5 | -0.27 | 4.4 | 0.29 | 1.37 |
| P(ANOVA) | ns | ns | ns | ns | |||||
CM = previous contraceptive method: 1 none, 2 oral contraceptive, 3 barrier method
ANOVA = Analysis of variance
T0, T1 = screening visit, after 1 month
T1-T0 = change in parameters after 1 month
Figure 2Mean impedance vectors with their 95% confidence ellipses at the screening visit, by previous contraception method. Mean impedance vectors with their 95% confidence ellipses at the screening visit. Labels to the vectors represent three groups according to the previous contraception method, vector a from 92 subjects following no method, vector b from 40 subjects taking oral contraceptives, and vector c from 41 subjects using barrier methods. Overlapping confidence ellipses indicate a comparable distribution of vectors among groups.
Figure 3Impedance vector displacements after 1 month, by previous contraception method. Impedance vector displacements (arrows) after 1 month. Labels to the vectors represent three groups according to the previous contraception method (as in Figure 2). Overlapping confidence ellipses indicate a comparable change of vectors in the three groups.