Literature DB >> 18727081

Balanced left ventricular myocardial SSFP-tagging at 1.5T and 3T.

M Markl1, S Scherer, A Frydrychowicz, D Burger, A Geibel, J Hennig.   

Abstract

The purpose of the study was to evaluate the performance of steady-state free precession (SSFP)-tagging at 1.5T and 3T and to define the ideal settings with respect to optimized tag contrast throughout the cardiac cycle for both field strengths. To identify optimal imaging parameters data acquisition was repeated for different flip angles. Left ventricular tag-tissue contrast, tag fading times, tag persistence, and myocardial signal-to-noise ratio (SNR) were quantified in basal, mid-ventricular, and apical slice locations. To assess the effect of field strength on image quality and artifact level, additional semiquantitative image grading was performed by two experienced readers. SSFP-tagging at 3T proved superior to 1.5T and provided significantly enhanced tag persistence and myocardial SNR while maintaining overall image quality and artifact level. The definition of a tag quality index demonstrated optimal SSFP-tagging performance for a flip angle of 20 degrees . Diastolic tag visibility was improved at 3T and resulted in enhanced average tag persistence of 789 +/- 128 ms compared to 523 +/- 40 ms at 1.5T. For SSFP-tagging at 3T the combination of T(1) lengthening and superior myocardial SNR is highly promising and has the potential to improve the depiction of tagged myocardial function throughout the entire cardiac cycle.

Mesh:

Year:  2008        PMID: 18727081     DOI: 10.1002/mrm.21674

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  6 in total

1.  Improved real-time tagged MRI using REALTAG.

Authors:  Weiyi Chen; Nam Gyun Lee; Dani Byrd; Shrikanth Narayanan; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2019-12-24       Impact factor: 4.668

2.  Myocardial motion analysis based on an optical flow method using tagged MR images.

Authors:  Daiki Tabata; Haruo Isoda; Kaori Kato; Hiroki Matsubara; Takafumi Kosugi; Takashi Kosugi; Masaki Terada; Atsushi Fukuyama; Yoshiaki Komori; Shinji Naganawa
Journal:  Radiol Phys Technol       Date:  2018-04-12

3.  Intermittently tagged real-time MRI reveals internal tongue motion during speech production.

Authors:  Weiyi Chen; Dani Byrd; Shrikanth Narayanan; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2019-03-28       Impact factor: 4.668

Review 4.  Comprehensive cardiac magnetic resonance imaging.

Authors:  Amy M West; Christopher M Kramer
Journal:  J Invasive Cardiol       Date:  2009-07       Impact factor: 2.022

Review 5.  Cardiovascular magnetic resonance at 3.0 T: current state of the art.

Authors:  John N Oshinski; Jana G Delfino; Puneet Sharma; Ahmed M Gharib; Roderic I Pettigrew
Journal:  J Cardiovasc Magn Reson       Date:  2010-10-07       Impact factor: 5.364

6.  Myocardial strain in healthy adults across a broad age range as revealed by cardiac magnetic resonance imaging at 1.5 and 3.0T: Associations of myocardial strain with myocardial region, age, and sex.

Authors:  Kenneth Mangion; Guillaume Clerfond; Christie McComb; David Carrick; Samuli M Rauhalammi; John McClure; David S Corcoran; Rosemary Woodward; Vanessa Orchard; Aleksandra Radjenovic; Xiaodong Zhong; Colin Berry
Journal:  J Magn Reson Imaging       Date:  2016-04-22       Impact factor: 4.813

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.