Literature DB >> 18725347

[Discrepancy between two methods of D-dimers measurement: one case of human anti-mouse antibody interference].

J A Rouvière1, J Devignes, E de Maistre, A Kennel, F Chabot, T Lecompte.   

Abstract

Quantification of D-dimers is the major biometry step in the diagnostic of an episode of the venous thromboembolic disease. The measurement of D-dimers can be performed with ELISA or immunoturbidimetric methods suited to emergency, using a mouse monoclonal antibody as capture and/or revelation antibody. Therefore, the presence in patient's plasma of human antibody mouse (HAMA) that binds the mouse antiglobulin used in immunoassays can lead to false negative or false positive results. In a young woman presenting repetitive thoracic pain suggestive of a pulmonary embolism, a major discrepancy was found between one result of D-dimers above the cut-off with an immunoturbidimetric method (STA Liatest D-DI; Diagnostica Stago) and one result below the cut-off with a sandwich method (Vidas D-Dimer Exclusion; bioMérieux). HAMA, which is known to be responsible for this type of discrepancy, was detected in the patient serum. The false positive result probably impaired with the management of patient. Taking in charge the patient should take into account the possible presence of this antibody. Interference by heterophilic antibodies is not easily detected by the laboratory. Even if their frequency is low, it remains a difficult problem for the biologist. Suspicion generally arises from inconsistency between the clinical data and immunoassay results. A good communication between physician and biologist should avoid to providing false negative or positive results.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18725347     DOI: 10.1684/abc.2008.0247

Source DB:  PubMed          Journal:  Ann Biol Clin (Paris)        ISSN: 0003-3898            Impact factor:   0.459


  3 in total

1.  What makes D-dimer assays suspicious-heterophilic antibodies?

Authors:  Ying Wu; Ying-Xiu Xiao; Teng-Yi Huang; Xian-Yan Zhang; Huan-Bing Zhou; Xue-Xuan Zhang; Ying-E Wu
Journal:  J Clin Lab Anal       Date:  2018-10-15       Impact factor: 2.352

2.  Analytical performance of a new immunoturbidimetric D-dimer assay and comparison with available assays.

Authors:  Laurie Talon; Virginie Fourneyron; Alexandre Trapani; Bruno Pereira; Thomas Sinegre; Aurélien Lebreton
Journal:  Res Pract Thromb Haemost       Date:  2022-02-06

3.  Identification of and solution for false D-dimer results.

Authors:  Xian-Yan Zhang; Xue-Xuan Zhang; Jia-Long Xu; Teng-Yi Huang; Ying Wu; Ye-Ru Yang; Huan-Bin Zhou; Ying-E Wu
Journal:  J Clin Lab Anal       Date:  2020-01-22       Impact factor: 2.352

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.