Some medical applications are associated with high doses to the extremities of the staff exposed to ionising radiation. At workplaces in nuclear medicine, interventional radiology, interventional cardiology and brachytherapy, extremities can be the limiting organs as far as regulatory dose limits for workers are concerned. However, although the need for routine extremity monitoring is clear for these applications, no data about the status of routine extremity monitoring reported by different countries was collected and analysed so far, at least at a European level. In this article, data collected from seven European countries are presented. They are compared with extremity doses extracted from dedicated studies published in the literature which were reviewed in a previous publication. The analysis shows that dedicated studies lead to extremity doses significantly higher than the reported doses, suggesting that either the most exposed workers are not monitored, or the dosemeters are not routinely worn or not worn at appropriate positions.

Mesh:

Year:  2008        PMID: 18723854     DOI: 10.1093/rpd/ncn229

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  3 in total

Review 1.  Personal dosimetry for interventional operators: when and how should monitoring be done?

Authors:  C J Martin
Journal:  Br J Radiol       Date:  2010-12-15       Impact factor: 3.039

2.  Exposure of treating physician to radiation during prostate brachytherapy using iodine-125 seeds: dose measurements on both hands with thermoluminescence dosimeters.

Authors:  Hans Schiefer; Friedrich von Toggenburg; Wolf Seelentag; Ludwig Plasswilm; Gerhard Ries; Cornelius Lenggenhager; Hans-Peter Schmid; Thomas Leippold; Ladislav Prikler; Bernd Krusche; Jakob Roth; Daniel Engeler
Journal:  Strahlenther Onkol       Date:  2009-10-06       Impact factor: 3.621

3.  Effect of dosimeter's position on occupational radiation extremity dose measurement for nuclear medicine workers during (18)F-FDG preparation for PET/CT.

Authors:  Fabien Salesses; Paul Perez; Aline E Maillard; Julie Blanchard; Sabine Mallard; Laurence Bordenave
Journal:  EJNMMI Phys       Date:  2016-08-05