Literature DB >> 18722308

Accuracy of knee range of motion assessment after total knee arthroplasty.

Carlos Lavernia1, Michele D'Apuzzo, Mark D Rossi, David Lee.   

Abstract

Measurement of knee joint range of motion (ROM) is important to assess after total knee arthroplasty. Our objective was to determine level of agreement and accuracy between observers with different knowledge on total ROM after total knee arthroplasty. Forty-one patients underwent x-ray of active and passive knee ROM (gold standard). Five different raters evaluated observed and measured ROM: orthopedic surgeon, clinical fellow, physician assistant, research fellow, and a physical therapist. A 1-way analysis of variance was used to determine differences in ROM between raters over both conditions. Limit of agreement for each rater for both active and passive total ROM under both conditions was calculated. Analysis of variance indicated a difference between raters for all conditions (range, P = .004 to P < or =.0001). The trend for all raters was to overestimate ROM at higher ranges. Assessment of ROM through direct observation without a goniometer provides inaccurate findings.

Entities:  

Mesh:

Year:  2008        PMID: 18722308     DOI: 10.1016/j.arth.2008.05.019

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  20 in total

1.  Validity and reliability of using photography for measuring knee range of motion: a methodological study.

Authors:  Justine M Naylor; Victoria Ko; Sam Adie; Clive Gaskin; Richard Walker; Ian A Harris; Rajat Mittal
Journal:  BMC Musculoskelet Disord       Date:  2011-04-18       Impact factor: 2.362

2.  High-flexion total knee arthroplasty improves flexion of stiff knees.

Authors:  Bum-Sik Lee; Jong-Min Kim; Sang-Jin Lee; Kwang-Hwan Jung; Dae-Hee Lee; Eun-Jong Cha; Seong-Il Bin
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-10-02       Impact factor: 4.342

3.  Extension gap needs more than 1-mm laxity after implantation to avoid post-operative flexion contracture in total knee arthroplasty.

Authors:  Shigetoshi Okamoto; Ken Okazaki; Hiroaki Mitsuyasu; Shuichi Matsuda; Hideki Mizu-Uchi; Satoshi Hamai; Yasutaka Tashiro; Yukihide Iwamoto
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-01-31       Impact factor: 4.342

4.  Active Flexion in Weight Bearing Better Correlates with Functional Outcomes of Total Knee Arthroplasty than Passive Flexion.

Authors:  Young Dong Song; Nimash Jain; Yeon Gwi Kang; Tae Yune Kim; Tae Kyun Kim
Journal:  Knee Surg Relat Res       Date:  2016-06-01

5.  Measurement of the knee flexion angle with smartphone applications: Which technology is better?

Authors:  Jean-Yves Jenny; Abdullah Bureggah; Yann Diesinger
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-02-15       Impact factor: 4.342

6.  Sagittal patellar flexion angle: a novel clinically validated patellar height measurement reflecting patellofemoral kinematics useful throughout knee flexion.

Authors:  Michael J Dan; James McMahon; William C H Parr; Nancy Briggs; Samuel MacDessi; Bruce Caldwell; William R Walsh
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-07-09       Impact factor: 4.342

7.  Predictors of range of motion in patients undergoing manipulation after TKA.

Authors:  Harpreet S Bawa; Glenn D Wera; Matthew J Kraay; Randall E Marcus; Victor M Goldberg
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

8.  Feasibility of a Home-Based Therapeutic Exercise Program in Individuals With Knee Osteoarthritis.

Authors:  Cristina Silva; António Amaro; António Pinho; Rui S Gonçalves; Mário Rodrigues; Fernando Ribeiro
Journal:  Arch Rheumatol       Date:  2018-01-15       Impact factor: 1.472

9.  Time-dependent improvement in functional outcome following Oxford medial unicompartmental knee arthroplasty. A prospective longitudinal multicenter study involving 96 patients.

Authors:  Tor Kjetil Nerhus; Stig Heir; Ida Svege; Inge Skråmm; Tore Jervidalo; Jan Erik Madsen; Arne Ekeland
Journal:  Acta Orthop       Date:  2012-01-17       Impact factor: 3.717

10.  Time-dependent improvement in functional outcome following LCS rotating platform knee replacement.

Authors:  Tor Kjetil Nerhus; Stig Heir; Elisabeth Thornes; Jan Erik Madsen; Arne Ekeland
Journal:  Acta Orthop       Date:  2010-11-11       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.