Literature DB >> 18719931

Quantification of acromioclavicular reduction parameters after the Weaver-Dunn procedure.

Murat Bezer1, Baransel Saygi, Nuri Aydin, Fatih Kucukdurmaz, Gazanfer Ekinci, Osman Guven.   

Abstract

BACKGROUND: The combination of the reconstruction of the coracoclavicular ligaments with the resection arthroplasty of the distal end of the clavicle is a commonly used technique in acromioclavicular separations. HYPOTHESIS: The purpose of the current study was to quantify the reduction parameters using 3-D CT and to analyze their effects on clinical outcomes. STUDY
DESIGN: Case series.
METHODS: The patients with chronic symptoms after acromioclavicular dislocation (type III) were treated with reconstruction of the coracoclavicular ligaments. The average follow-up was 69.5 months. The patient group consisted of 21 men and 8 women. The initial treatment at the time of injury was nonoperative in 26 of 29 patients. CT was used to document anteroposterior (APD), craniocaudal (CCD) and mediolateral (MLD) acromioclavicular reduction parameters. Constant Shoulder scoring system was used.
RESULTS: The mean preoperative Constant score was 56.62 +/- 18.63 points while the postoperative score was 89.93 +/- 10.79 points. The mean APD was 9.2 mm, the mean CCD was 1.1 mm and the mean MLD was 8.4 mm. There was no correlation between the APD, MLD and the Constant Scores. However, an inverse correlation between the CCD and the postoperative Constant Scores was found.
CONCLUSIONS: CCD plays an important role on the postoperative function. If the CCD is larger, the Constant score is lower. CLINICAL RELEVANCE: The reduction loss is a distinctive parameter of the functional outcome, even when the reconstructed coracoclavicular ligament is intact. Secure fixation may be achieved with techniques preserving CCD.

Entities:  

Mesh:

Year:  2008        PMID: 18719931     DOI: 10.1007/s00402-008-0723-6

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  6 in total

1.  Anatomic and non-anatomic reconstruction improves post-operative outcomes in chronic acromio-clavicular instability: a systematic review.

Authors:  Francisco Xará-Leite; Renato Andrade; Pedro Silva Moreira; Luís Coutinho; Olufemi R Ayeni; Nuno Sevivas; João Espregueira-Mendes
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-02-26       Impact factor: 4.342

Review 2.  Anatomic reconstruction of the acromioclavicular joint provides the best functional outcomes in the treatment of chronic instability.

Authors:  Giuseppe Sircana; Maristella F Saccomanno; Fabrizio Mocini; Vincenzo Campana; Piermarco Messinese; Andrea Monteleone; Andrea Salvi; Alessandra Scaini; Almerico Megaro; Giuseppe Milano
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-05-27       Impact factor: 4.342

3.  Evaluation of the use of the hook plate in Neer type 2 lateral clavicle fractures and Rockwood types 3-5 acromioclavicular joint dislocations.

Authors:  C C Drijfhout van Hooff; R Haverlag; W J Willems
Journal:  Eur J Trauma Emerg Surg       Date:  2013-06-27       Impact factor: 3.693

4.  Distal Clavicle Osteolysis after Modified Weaver-Dunn's Procedure for Chronic Acromioclavicular Dislocation: A Case Report and Review of Complications.

Authors:  Eduard Alentorn-Geli; Fernando Santana; Felipe Mingo; Ignasi Piñol; Albert Solano; Lluís Puig-Verdié; Carles Torrens
Journal:  Case Rep Orthop       Date:  2014-12-02

5.  A combined technique for acromioclavicular reconstruction after acute dislocation - technical description and functional outcomes.

Authors:  Diogo Lino Moura; Augusto Reis E Reis; João Ferreira; Manuel Capelão; José Braz Cardoso
Journal:  Rev Bras Ortop       Date:  2017-03-23

6.  Modified Weaver-Dunn Procedure for Type 3 Acromioclavicular Joint Dislocation: Functional and Radiological Outcomes.

Authors:  Olimpio Galasso; Lorenzo Tarducci; Massimo De Benedetto; Nicola Orlando; Michele Mercurio; Giorgio Gasparini; Roberto Castricini
Journal:  Orthop J Sports Med       Date:  2020-03-06
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.