Literature DB >> 18719051

A comparison of the reproducibility of manual tracing and on-screen digitization for cephalometric profile variables.

D P Dvortsin1, A Sandham, G J Pruim, P U Dijkstra.   

Abstract

The aim of this investigation was to analyse and compare the reproducibility of manual cephalometric tracings with on-screen digitization using a soft tissue analysis. A random sample of 20 lateral cephalometric radiographs, in the natural head posture, was selected. On-screen digitization using Viewbox 3.1.1.9 cephalometric software and manual tracing on a 1:1 printout of the image was carried out twice in different sessions 1 week apart. Differences were analysed using a repeated measurement analysis of variance with method, session, and method-session interaction as explaining variables. The differences were expressed as an absolute percentage of the overall mean. The findings of the present study indicate that the two measurement methods differ significantly for 11 variables (P = 0.001 to P = 0.042). The area around stomion was the least reproducible. Except for s-n(s)-unt, nasal protrusion, with the manual technique, all mean differences between sessions and between methods were less than 1 degree or 1 mm and were, on-screen, smaller for 13 variables compared with those traced manually. Absolute percentage differences of the overall mean were smaller for seven variables with the digital technique and three variables in the manual technique, while four manual variables and one on-screen variable exceeded 2 per cent of the overall mean. Although small significant differences were found, the clinical relevance remains questionable.

Mesh:

Year:  2008        PMID: 18719051     DOI: 10.1093/ejo/cjn041

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  4 in total

1.  Concurrent validity and reliability of cephalometric analysis using smartphone apps and computer software.

Authors:  Christos Livas; Konstantina Delli; Frederik K L Spijkervet; Arjan Vissink; Pieter U Dijkstra
Journal:  Angle Orthod       Date:  2019-07-08       Impact factor: 2.079

2.  Evaluation of soft tissue prediction accuracy for orthognathic surgery with skeletal class III malocclusion using maxillofacial regional aesthetic units.

Authors:  Lei Hou; Yang He; Biao Yi; Xiaoxia Wang; Xiaojing Liu; Yi Zhang; Zili Li
Journal:  Clin Oral Investig       Date:  2022-09-26       Impact factor: 3.606

3.  Reliability of the integrated radiograph-photograph method to obtain natural head position in cephalometric diagnosis.

Authors:  Dima P Dvortsin; Qingsong Ye; Gerard J Pruim; Pieter U Dijkstra; Yijin Ren
Journal:  Angle Orthod       Date:  2011-05-04       Impact factor: 2.079

4.  Efficacy of a Newly Designed Cephalometric Analysis Software for McNamara Analysis in Comparison with Dolphin Software.

Authors:  Mahtab Nouri; Shadi Hamidiaval; Alireza Akbarzadeh Baghban; Mohammad Basafa; Mohammad Fahim
Journal:  J Dent (Tehran)       Date:  2015-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.