Literature DB >> 18718766

Repair integrity and clinical outcome after arthroscopic rotator cuff repair using single-row anchor fixation: a prospective study of single-tendon and two-tendon tears.

Allen Deutsch1, Derek G Kroll, Joseph Hasapes, R Scott Staewen, Cynthia Pham, Cindy Tait.   

Abstract

This prospective study determined whether single-row anchor fixation would reliably improve clinical outcome and maintain structural integrity after arthroscopic repair of single-tendon and 2-tendon rotator cuff tears. In 39 patients, 21 shoulders had single-tendon tears and 18 had 2-tendon tears. Mean follow-up was 38 months (minimum, 24 months). A standardized assessment was done preoperatively and postoperatively at yearly intervals. Postoperative magnetic resonance imaging (MRI) was performed at a minimum 1-year follow-up. Mean forward elevation, pain, satisfaction, and American Shoulder and Elbow Surgeons scores significantly improved for both groups (P < .01). Postoperative MRI examinations showed 19 cuffs (90%) were intact for single-tendon tears and 15 (83%) were intact for 2-tendon tears. A recurrent tear on postoperative MRI was significantly correlated with the intraoperative finding of asymmetric retraction. Arthroscopic rotator cuff repair using single-row anchor fixation resulted in significant improvements in clinical outcome and reliable repair integrity for both single-tendon and 2-tendon tears.

Entities:  

Mesh:

Year:  2008        PMID: 18718766     DOI: 10.1016/j.jse.2008.04.004

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  6 in total

Review 1.  Single versus double-row repair of the rotator cuff: does double-row repair with improved anatomical and biomechanical characteristics lead to better clinical outcome?

Authors:  Stephan Pauly; Christian Gerhardt; Jianhai Chen; Markus Scheibel
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-08-25       Impact factor: 4.342

2.  The effect of multiple channeling on the structural integrity of repaired rotator cuff.

Authors:  Chris Hyunchul Jo; Kang Sup Yoon; Ji Ho Lee; Seung Baik Kang; Jae Hyup Lee; Hyuk Soo Han; Seung Hwan Rhee; Ji Sun Shin
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-04-30       Impact factor: 4.342

Review 3.  Magnetic resonance imaging criteria for the assessment of the rotator cuff after repair: a systematic review.

Authors:  Maristella F Saccomanno; Gianpiero Cazzato; Mario Fodale; Giuseppe Sircana; Giuseppe Milano
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-01-04       Impact factor: 4.342

4.  Characteristics and stimulation potential with BMP-2 and BMP-7 of tenocyte-like cells isolated from the rotator cuff of female donors.

Authors:  Franka Klatte-Schulz; Stephan Pauly; Markus Scheibel; Stefan Greiner; Christian Gerhardt; Jelka Hartwig; Gerhard Schmidmaier; Britt Wildemann
Journal:  PLoS One       Date:  2013-06-25       Impact factor: 3.240

5.  Functional outcomes of traumatic and non-traumatic rotator cuff tears after arthroscopic repair.

Authors:  José Jorge Kitagaki Abechain; Glaydson Gomes Godinho; Fabio Teruo Matsunaga; Nicola Archetti Netto; Julia Pozzetti Daou; Marcel Jun Sugawara Tamaoki
Journal:  World J Orthop       Date:  2017-08-18

Review 6.  The effect of age on risk of retear after rotator cuff repair: a systematic review and meta-analysis.

Authors:  Michael Khazzam; Brian Sager; Hayden N Box; Steven B Wallace
Journal:  JSES Int       Date:  2020-06-10
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.