Literature DB >> 18716540

Irrigation eliminates smoke formation in laser laparoscopic surgery: ex vivo results.

Jun-Hao Liang1, Chuan-Liang Xu, Lin-Hui Wang, Jian-Guo Hou, Xiao-Feng Gao, Ying-Hao Sun.   

Abstract

BACKGROUNDS AND
OBJECTIVES: To evaluate the desmoke effects of irrigation on surgical smoke generated during laser laparoscopic surgery using ex vivo model. STUDY DESIGN/
MATERIALS AND METHODS: A hand-piece was devised as both an irrigation tube and a laser fiber holder. The laser system used was a diode pumped continuous wave Thulium YAG laser (Lisa laser products OHG, Katlenburg-Lindau, Germany) emitting at 2.01-mum through a quartz fiber with a core diameter of 365 mum. Using a transparent container as experimental model (approximately 3 L in volume), 6 irrigation rates (0, 20, 40, 60, 80, and 100 mL/min) were tested combining with 4 laser power settings (20, 30, 40, and 50 W). To evaluate the desmoke efficiency of irrigation, lasing time with effective visibility under different combination of irrigation rates and laser powers were documented, and corresponding smoke generation rate were calculated (=3 L/lasing time). Analysis of variance was used to compare difference and significance was indicated at P<0.05.
RESULTS: Calculated smoke generation rate was increased with laser power whereas decreased with irrigation rate. At 4 tested laser powers, calculated smoke generation rates were high (mean: 91.4 to 306.6 mL/s) when no water presented, but were significantly decreased (mean: 12.6 to 55.0 mL/s, P<0.001) with the lowest water flow rate (20 mL/min) and further decreased with higher rates. The proper range of irrigation rate for future clinical practice would be around 40 mL/min.
CONCLUSIONS: Irrigation eliminates smoke formation accompanying laser tissue irradiation. It shows promise for future application in laser laparoscopic surgery.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18716540     DOI: 10.1097/SLE.0b013e318175ddfc

Source DB:  PubMed          Journal:  Surg Laparosc Endosc Percutan Tech        ISSN: 1530-4515            Impact factor:   1.719


  1 in total

1.  A 2-microm continuous-wave laser system for safe and high-precision dissection during NOTES procedures.

Authors:  Xavier Dray; Gianfranco Donatelli; Devi Mukkai Krishnamurty; Elena Dubcenco; Ronald J Wroblewski; Lia Assumpcao; Samuel A Giday; Jonathan M Buscaglia; Eun J Shin; Priscilla Magno; Laurie J Pipitone; Michael R Marohn; Sergey V Kantsevoy; Anthony N Kalloo
Journal:  Dig Dis Sci       Date:  2010-09       Impact factor: 3.199

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.