Literature DB >> 18715391

Automated versus manual blood pressure measurement: a randomized crossover trial.

Megan Heinemann1, Ken Sellick, Claire Rickard, Pam Reynolds, Matthew McGrail.   

Abstract

This study evaluated the accuracy and reliability of the Dinamap 8100 automated blood pressure machine against three internationally recognized criteria. Systolic and diastolic blood pressures were taken concurrently by two nurses using the automated machine and a manual sphygmomanometer. Results demonstrated agreement between automated and manual readings on one set of criteria for both systolic and diastolic pressures, and support for systolic readings only on one other criterion. Comparison of mean differences between automated and manual measures showed the automated machine consistently under-read both systolic and diastolic blood pressures. The conclusion from this study was that the Dinamap 8100 machine can be used with some degree of confidence to assess systolic blood pressures in a general population of adult hospital inpatients, but with caution when taking diastolic readings.

Entities:  

Mesh:

Year:  2008        PMID: 18715391     DOI: 10.1111/j.1440-172X.2008.00696.x

Source DB:  PubMed          Journal:  Int J Nurs Pract        ISSN: 1322-7114            Impact factor:   2.066


  9 in total

1.  Blood pressure measurement guidelines for physical therapists.

Authors:  Ethel M Frese; Ann Fick; H Steven Sadowsky
Journal:  Cardiopulm Phys Ther J       Date:  2011-06

2.  Preterm birth and long-term maternal cardiovascular health.

Authors:  Wei Perng; Jennifer Stuart; Sheryl L Rifas-Shiman; Janet W Rich-Edwards; Alison Stuebe; Emily Oken
Journal:  Ann Epidemiol       Date:  2014-10-18       Impact factor: 3.797

3.  Automated Versus Manual Blood Pressure Measurement: A Randomized Crossover Trial in the Emergency Department of a Tertiary Care Hospital in Karachi, Pakistan: Are Third World Countries Ready for the Change?

Authors:  Kanaan Mansoor; Saba Shahnawaz; Mariam Rasool; Huwad Chaudhry; Gul Ahuja; Sara Shahnawaz
Journal:  Open Access Maced J Med Sci       Date:  2016-07-27

Review 4.  Sources of inaccuracy in the measurement of adult patients' resting blood pressure in clinical settings: a systematic review.

Authors:  Noa Kallioinen; Andrew Hill; Mark S Horswill; Helen E Ward; Marcus O Watson
Journal:  J Hypertens       Date:  2017-03       Impact factor: 4.844

5.  Comparisons between different blood pressure measurement techniques in patients with chronic kidney disease.

Authors:  Shahrokh Ezzatzadegan Jahromi; Ghasem Haghighi; Jamshid Roozbeh; Vahid Ebrahimi
Journal:  Kidney Res Clin Pract       Date:  2019-06-30

6.  Current utility of the ankle-brachial index (ABI) in general practice: implications for its use in cardiovascular disease screening.

Authors:  Jane H Davies; Joyce Kenkre; E Mark Williams
Journal:  BMC Fam Pract       Date:  2014-04-17       Impact factor: 2.497

7.  Comparison of manual versus automated blood pressure measurement in intensive care unit, coronary care unit, and emergency room.

Authors:  Ahmad Mirdamadi; Mostafa Etebari
Journal:  ARYA Atheroscler       Date:  2017-01

8.  Vascular Endothelial Function in Midlife/Older Adults Classified According to 2017 American College of Cardiology/American Heart Association Blood Pressure Guidelines.

Authors:  Daniel H Craighead; Kaitlin A Freeberg; Douglas R Seals
Journal:  J Am Heart Assoc       Date:  2020-08-20       Impact factor: 5.501

9.  Availability, functionality and access of blood pressure machines at the points of care in public primary care facilities in Tororo district, Uganda.

Authors:  Innocent K Besigye; Vicent Okuuny; Mari Armstrong-Hough; Anne R Katahoire; Nelson K Sewankambo; Robert Mash; Achilles Katamba
Journal:  S Afr Fam Pract (2004)       Date:  2021-01-11
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.