Literature DB >> 18711570

An attenuation-partition based iterative phase retrieval algorithm for in-line phase-contrast imaging.

Aimin Yan1, Xizeng Wu, Hong Liu.   

Abstract

For medical applications of the in-line phase-contrast x-ray imaging, phase retrieval is a crucial step for quantitative imaging such as reconstructing the 3-D distribution of tissue linear attenuation coefficients and refraction indices. The conventional phase retrieval algorithms, such as the transport of intensity equation (TIE) based algorithms, are not robust against the quantum noise that appears in acquired images due to the radiation dose constraints in medical imaging. In this work a new attenuation-partition based iterative phase retrieval algorithm is proposed. This new algorithm takes advantage of the correlation between the attenuation and phase-shift, and is much robust against noise in acquired images. Phase retrieval results from experimental images show that this new iterative algorithm is fast and robust, and it has good potential for medical x-ray imaging applications.

Mesh:

Year:  2008        PMID: 18711570     DOI: 10.1364/oe.16.013330

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  6 in total

1.  Robustness of phase retrieval methods in X-ray phase contrast imaging: a comparison.

Authors:  Aimin Yan; Xizeng Wu; Hong Liu
Journal:  Med Phys       Date:  2011-09       Impact factor: 4.071

2.  Performance analysis of the attenuation-partition based iterative phase retrieval algorithm for in-line phase-contrast imaging.

Authors:  Aimin Yan; Xizeng Wu; Hong Liu
Journal:  Opt Express       Date:  2010-07-19       Impact factor: 3.894

3.  A robust general phase retrieval method for medical applications.

Authors:  A Yan; X Wu; H Liu
Journal:  J Instrum       Date:  2013-05-24       Impact factor: 1.415

Review 4.  Potential for imaging engineered tissues with X-ray phase contrast.

Authors:  Alyssa Appel; Mark A Anastasio; Eric M Brey
Journal:  Tissue Eng Part B Rev       Date:  2011-08-02       Impact factor: 6.389

5.  Dose and detectability improvements with high energy phase sensitive x-ray imaging in comparison to low energy conventional imaging.

Authors:  Molly Donovan Wong; Aimin Yan; Muhammad Ghani; Yuhua Li; Laurie Fajardo; Xizeng Wu; Hong Liu
Journal:  Phys Med Biol       Date:  2014-04-15       Impact factor: 3.609

6.  Image quality and dose efficiency of high energy phase sensitive x-ray imaging: phantom studies.

Authors:  Molly Donovan Wong; Xizeng Wu; Hong Liu
Journal:  J Xray Sci Technol       Date:  2014       Impact factor: 1.535

  6 in total