Literature DB >> 18711242

Efficient use of continuous, real-time prostate localization.

Kathleen T Malinowski1, Camille Noel, Meghana Roy, Twyla Willoughby, Toufik Djemi, Shirish Jani, Timothy Solberg, David Liu, Lisa Levine, Parag J Parikh.   

Abstract

Recent technological advances make it possible to monitor prostate movement during radiation delivery. Using previously published data from 35 patients who underwent continuous localization during prostate cancer treatment, we simulated various interventions to identify the radiation-gating and patient-repositioning strategies that least prolonged the time to complete the daily treatment. Acceptable response protocols were those that resulted in at least 95% of patients' prostates remaining within the planning margins at least 95% of the time. Gating and repositioning were not necessary for margins of 7 or 10 mm because of the rarity of excursions at these margins. However, intervention was routinely necessary for margins of 3 and 5 mm. In simulated interventions for which the therapist could reposition the treatment couch without entering the room, the most time-efficient response protocol was to reposition the couch immediately after the prostate position was outside the treatment margins. In simulations in which the therapist had to enter the room to reposition the couch, overall treatment time could be reduced and accuracy could be increased by manually gating treatment for 11 and 21 s for 3- and 5-mm margins, respectively, before interrupting treatment to reposition the treatment couch.

Entities:  

Mesh:

Year:  2008        PMID: 18711242     DOI: 10.1088/0031-9155/53/18/007

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Optimized hybrid megavoltage-kilovoltage imaging protocol for volumetric prostate arc therapy.

Authors:  Wu Liu; Rodney D Wiersma; Lei Xing
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-05-14       Impact factor: 7.038

2.  Sensitivity of postplanning target and OAR coverage estimates to dosimetric margin distribution sampling parameters.

Authors:  Huijun Xu; J James Gordon; Jeffrey V Siebers
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

3.  Determination of action thresholds for electromagnetic tracking system-guided hypofractionated prostate radiotherapy using volumetric modulated arc therapy.

Authors:  Pengpeng Zhang; Dennis Mah; Laura Happersett; Brett Cox; Margie Hunt; Gig Mageras
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

4.  Clinical development of a failure detection-based online repositioning strategy for prostate IMRT--experiments, simulation, and dosimetry study.

Authors:  Wu Liu; Jianguo Qian; Steven L Hancock; Lei Xing; Gary Luxton
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

5.  Analysis of prostate patient setup and tracking data: potential intervention strategies.

Authors:  Zhong Su; Lisha Zhang; Martin Murphy; Jeffrey Williamson
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-10-08       Impact factor: 7.038

6.  Automatic prostate tracking and motion assessment in volumetric modulated arc therapy with an electronic portal imaging device.

Authors:  Juan Diego Azcona; Ruijiang Li; Edward Mok; Steven Hancock; Lei Xing
Journal:  Int J Radiat Oncol Biol Phys       Date:  2013-04-19       Impact factor: 7.038

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.