Stability of hematological analytes depends on the hematology analyser used: a stability study with Bayer Advia 120, Beckman Coulter LH 750 and Sysmex XE 2100.

Fatime Imeri1, Roberto Herklotz, Lorenz Risch, Christine Arbetsleitner, Manfred Zerlauth, Gerhard M Risch, Andreas R Huber.   

Abstract

AIM: With the availability of newer hematology analysers, novel measurement techniques are being introduced into daily routine. As analyte stability may differ according to the employed measurement technique, the aim of this study was to assess the stability of hematologic analytes on different hematology analysers.
METHODS: We investigated the effect of storage time and storage temperature on sample stability on three newer analytical systems (Advia 120, Bayer Diagnostics; XE 2100, Sysmex and LH 750, Beckman Coulter). Samples were obtained from 64 healthy volunteers and stored at room temperature as well at 4-8 degrees C in order to conduct analysis at different timepoints up to 72 h after blood was drawn. Sample stability was assessed by the graphical truncated normal sequential test. A parameter was considered stable, when its average change was smaller than one coefficient of variation CV (%) of the assessed method, allowing a 5% risk of error.
RESULTS: Red blood cell counts, mean corpuscular hemoglobin (MCH) and hemoglobin are least affected by storage temperature and showed stability for at least 48 h, depending on analyser utilized. While reticulocytes, mean corpuscular volume (MCV), hematocrit and leukocyte counts were more stable at 4-8 degrees C, thrombocytes exhibited a better stability at RT. The white blood cell (WBC) subpopulations changed over time with a decrease in eosinophils and lymphocytes and an increase in neutrophils at 4-8 degrees C. Further, the stability pattern of WBC subpopulations was significantly different among the 3 investigated analysers with some analytes only displaying a stability of 4 h.
CONCLUSIONS: Analyte stability of hematological parameters varies not only according to the investigated parameter but also according to storage temperature and the employed measurement system. Depending on the analyte sample stability differences among the different analytical systems are considerable.

Mesh:

Year:  2008        PMID: 18706900     DOI: 10.1016/j.cca.2008.07.018

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  17 in total

Review 1.  Stability of haematological parameters and its relevance on the athlete's biological passport model.

Authors:  Giovanni Lombardi; Patrizia Lanteri; Alessandra Colombini; Giuseppe Lippi; Giuseppe Banfi
Journal:  Sports Med       Date:  2011-12-01       Impact factor: 11.136

2.  Evaluation of the Performance of the Sysmex XT-2000i Hematology Analyzer With Whole Bloods Stored at Room Temperature.

Authors:  Valerie L Hill; Virginia Z Simpson; Jeanette M Higgins; Zonghui Hu; Randy A Stevens; Julie A Metcalf; Michael Baseler
Journal:  Lab Med       Date:  2009-12

3.  Value of neutrophil lymphocyte ratio in patients with hepatocellular carcinoma undergoing TAE combined with Sorafenib.

Authors:  Mehmet Agilli; Fevzi Nuri Aydin; Yasemin Gulcan Kurt
Journal:  Med Oncol       Date:  2014-06-14       Impact factor: 3.064

4.  Does the moderator matter? Identification of multiple moderators of the association between peripheral inflammatory markers and depression severity in a large racially diverse community cohort.

Authors:  Manivel Rengasamy; Sophia Arruda Da Costa E Silva; Meredith Spada; Rebecca B Price
Journal:  Neuropsychopharmacology       Date:  2022-05-20       Impact factor: 8.294

5.  Two different hematocrit detection methods: different methods, different results?

Authors:  Marco Bosshart; John F Stover; Reto Stocker; Lars M Asmis; Jörg Feige; Thomas A Neff; Reto A Schuepbach; Silvia R Cottini; Markus Béchir
Journal:  BMC Res Notes       Date:  2010-03-09

6.  Artifactual changes in Sprague-Dawley rat hematologic parameters after storage of samples at 3 °C and 21 °C.

Authors:  Michelle C Cora; Debra King; Laura J Betz; Ralph Wilson; Greg S Travlos
Journal:  J Am Assoc Lab Anim Sci       Date:  2012       Impact factor: 1.232

7.  Stability of hematological analytes during 48 hours storage at three temperatures using Cell-Dyn hematology analyzer.

Authors:  Ozmen Sevda Unalli; Yesim Ozarda
Journal:  J Med Biochem       Date:  2021-06-05       Impact factor: 3.402

8.  Mean Corpuscular Volume as a Marker for Adherence to Zidovudine-Containing Therapy in HIV-Infected Adults.

Authors:  Joseph O Mugisha; Katherine Donegan; Sarah Fidler; Gita Ramjee; Andrew Hodson; David T Dunn; Kholoud Porter; Pontiano Kaleebu
Journal:  Open AIDS J       Date:  2012-05-31

9.  The Importance of Total Neutrophil Count and Neutrophil/Lymphocyte Ratio in ST Elevation Myocardial Infarction.

Authors:  Mehmet Agilli; Ibrahim Aydin; Fevzi Nuri Aydin; Tuncer Cayci; Yasemin Gulcan Kurt
Journal:  J Cardiovasc Thorac Res       Date:  2014-12-30

10.  Effect of the addition of the antioxidant taurine on the complete blood count of whole blood stored at room temperature and at 4ºC for up to 7 days.

Authors:  Mahmoud Mohammed Sirdah; Abdelnasser Kassem Abushahla; Heba Abd Allah Al-Sarraj
Journal:  Rev Bras Hematol Hemoter       Date:  2013
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.