Literature DB >> 18706338

Determination of selected phenothiazines in human plasma by solid-phase extraction and liquid chromatography with coulometric detection.

Maria Addolorata Saracino1, Mario Amore, Elena Baioni, Carmine Petio, Maria Augusta Raggi.   

Abstract

A new analytical method, based on liquid chromatography with coulometric detection, has been developed and applied to the determination of selected phenothiazines (chlorpromazine, promazine, fluphenazine and levomepromazine) in human plasma. The drugs were separated on a Discovery pentafluorophenylpropyl column, using a mobile phase composed of acetonitrile (32%) and a pH 1.9 phosphate buffer (68%). Promethazine was used as the internal standard. Detection was carried out at an oxidation potential of +0.500 V. A novel clean-up procedure was developed by means of solid-phase extraction, using cyanopropyl cartridges, which gave good extraction yield for all the analytes, with absolute recovery values higher than 91.0%. The detector response was linear over a plasma concentration range of 0.5-250.0 ng mL(-1) for chlorpromazine, promazine and levomepromazine and of 0.2-4.0 ng mL(-1) for fluphenazine. Precision results, expressed by the intra-day and the inter-day relative standard deviation values, were good, being lower than 3.9%. Accuracy data were satisfactory as well. The method has been successfully applied to the analysis of drug plasma levels of psychiatric patients undergoing therapy with selected phenothiazines.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18706338     DOI: 10.1016/j.aca.2008.06.040

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  4 in total

1.  Dispersive liquid-liquid microextraction combined with high-performance liquid chromatography for the determination of clozapine and chlorpromazine in urine.

Authors:  Jing Chen; Chaomei Xiong; Jinlan Ruan; Zou Su
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2011-04-20

2.  Interaction of the human plasma membrane monoamine transporter (hPMAT) with antidepressants and antipsychotics.

Authors:  Britta Haenisch; Heinz Bönisch
Journal:  Naunyn Schmiedebergs Arch Pharmacol       Date:  2009-12-10       Impact factor: 3.000

3.  Ionophore-based potentiometric sensors for the flow-injection determination of promethazine hydrochloride in pharmaceutical formulations and human urine.

Authors:  Ahmed Khudhair Hassan; Bahruddin Saad; Sulaiman Ab Ghani; Rohana Adnan; Afidah Abdul Rahim; Norariza Ahmad; Marina Mokhtar; Suham Tawfiq Ameen; Suad Mustafa Al-Araji
Journal:  Sensors (Basel)       Date:  2011-01-18       Impact factor: 3.576

4.  Enantioseparation of phenothiazines through capillary electrophoresis with solid phase extraction and polymer based stacking.

Authors:  Wei-Bin Tseng; Ming-Mu Hsieh; Tai-Chia Chiu; Po-Lin Yu; Szu-Hua Chen
Journal:  J Food Drug Anal       Date:  2018-01-12       Impact factor: 6.157

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.