Literature DB >> 18704242

A biomechanical comparison of external skeletal fixation and plating for the stabilization of ilial osteotomies in dogs.

N Fitzpatrick1, D Lewis, A Cross.   

Abstract

This in vitro study compares the biomechanical properties of two methods of ilial fracture repair in dogs. Ten pelves were harvested from skeletally mature mixed breed dogs weighing 20-27 kg and bilateral oblique ilial body osteotomies were created. One hemipelvis from each dog was stabilized with a 2.7 mm plate and screws and the contralateral hemipelvis was stabilized with a five pin linear external fixator construct. Each hemipelvis was mounted at an angle of 30 degrees to an actuator platform, such that the acetabulum was centrally loaded by a steel sphere attached to the load cell of a servohydraulic materials testing machine. The construct was loaded at a constant rate of 20 mm/min. A load/displacement curve was generated for each hemipelvis by plotting the sustained load against the actuator movement. The stiffness, yield load and failure load for each hemipelvis were determined from the load/displacement curve. Bending stiffness was defined as the slope of the load/displacement curve from 100 N to yield load. The mode of failure was determined by observations made during testing and gross inspection of each specimen. The mean construct stiffness, yield load and failure load were compared between stabilization groups using a Student's paired t-test with statistical significance set at p<0.05. Nine out of 10 of the hemipelves that were stabilized by plates and screws failed catastrophically by fracture through the caudal screw holes and nine out of 10 of the hemipelves that were stabilized using an external fixator failed by fracture of the ischium in the region supported by the mounting roller, propagating through the most caudal ischial pin. There was not any significant difference (P=0.22) in bending stiffness between stabilization techniques, but yield (1467 N vs 2620 N; P=0.04) and failure (1918 N vs 2687 N; P=0.002) loads were significantly greater for hemipelves stabilized with external fixators.

Entities:  

Mesh:

Year:  2008        PMID: 18704242     DOI: 10.3415/vcot-06-10-0072

Source DB:  PubMed          Journal:  Vet Comp Orthop Traumatol        ISSN: 0932-0814            Impact factor:   1.358


  3 in total

1.  A biomechanical comparison of conventional dynamic compression plates and string-of-pearls™ locking plates using cantilever bending in a canine Ilial fracture model.

Authors:  Allison R Kenzig; James R Butler; Lauren B Priddy; Kristen R Lacy; Steven H Elder
Journal:  BMC Vet Res       Date:  2017-07-13       Impact factor: 2.741

2.  Preliminary study on a novel dedicated plate for iliac fractures in dogs.

Authors:  Tryssia S M Moi; Bruno W Minto; Ana P Macedo; Dayvid V F Lucena; Caio A S Malta; Luis G G G Dias
Journal:  PLoS One       Date:  2022-08-26       Impact factor: 3.752

3.  Case Report: Trans-Articular External Skeletal Fixation of the Hip for a Highly Comminuted Juxta-Articular Fracture of the Proximal Femur Caused by Gunshot Injury in a Cat.

Authors:  Hyun-Jung Han; Kyeongpung Lee; Hun-Young Yoon
Journal:  Front Vet Sci       Date:  2021-07-19
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.