Mechanical testing of 3.5 mm locking and non-locking bone plates.

M DeTora1, K Kraus.   

Abstract

Locking plate technologies are being developed in order to provide the surgeon with advantages over previous bone plate systems (both locking and non-locking). Locking plate systems possess inherent biological advantages in fracture fixation by preserving the periosteal blood supply, serving as internal fixators. It is important to consider the strength of each orthopaedic implant as an important selection criterion while utilizing the reported advantages of locking plate systems to prevent catastrophic fracture failure. Mechanical testing of orthopaedic implants is a common method used to provide a surgeon with insight on mechanical capabilities, as well as to form a standardized method of plate comparison. The purpose of this study was to demonstrate and to quantify observed differences in the bending strength between the LCP (Limited Contact Plate), LC-DCP, 3.5 mm Broad LC-DCP (Limited Contact Dynamic Compression Plate), and SOP (String of Pearls) orthopaedic bone plates. The study design followed the ASTM standard test method for static bending properties of metallic bone plates, which is designed to measure mechanical properties of bone plates subjected to bending, the most common loading encountered in vivo. Single cycle four point bending was performed on each orthopaedic implant. The area moment of inertia, bending stiffness, bending strength, and bending structural stiffness were calculated for each implant. The results of this study demonstrated significant differences (p<0.001) in bending strength and stiffness between the four orthopaedic implants (3.5 Broad LC-DCP>SOP>LCP=LC-DCP). The 3.5 mm LCP should be expected to provide in vivo strength and stiffness similar to a comparable LC-DCP. The SOP should provide strength and stiffness that is greater than a comparable LC-DCP but less than a 3.5 mm Broad LC-DCP.

Entities:  

Mesh:

Year:  2008        PMID: 18704237     DOI: 10.3415/vcot-07-04-0034

Source DB:  PubMed          Journal:  Vet Comp Orthop Traumatol        ISSN: 0932-0814            Impact factor:   1.358


  7 in total

1.  Orthopedic hardware and equipment for the beginner. Part 2: plates and screws.

Authors:  Greg Harasen
Journal:  Can Vet J       Date:  2011-12       Impact factor: 1.008

2.  Biomechanical investigation of an alternative concept to angular stable plating using conventional fixation hardware.

Authors:  Markus Windolf; Kajetan Klos; Dirk Wähnert; Bas van der Pol; Roman Radtke; Karsten Schwieger; Roland P Jakob
Journal:  BMC Musculoskelet Disord       Date:  2010-05-21       Impact factor: 2.362

3.  A study on the mechanical characteristics of the EBM-printed Ti-6Al-4V LCP plates in vitro.

Authors:  Peng-Cheng Liu; Yun-Ji Yang; Run Liu; He-Xi Shu; Jin-Peng Gong; Yong Yang; Qi Sun; Xing Wu; Ming Cai
Journal:  J Orthop Surg Res       Date:  2014-11-05       Impact factor: 2.359

4.  A biomechanical comparison of conventional dynamic compression plates and string-of-pearls™ locking plates using cantilever bending in a canine Ilial fracture model.

Authors:  Allison R Kenzig; James R Butler; Lauren B Priddy; Kristen R Lacy; Steven H Elder
Journal:  BMC Vet Res       Date:  2017-07-13       Impact factor: 2.741

5.  Retrospective evaluation of perioperative and short term clinical outcomes in appendicular long bone skeleton fractures repaired via the string of pearls (SOP) locking plate system.

Authors:  Matthew R Field; Ryan Butler; Robert W Wills; Wilburn M Maxwell
Journal:  BMC Vet Res       Date:  2018-12-05       Impact factor: 2.741

6.  The effect of contouring on fatigue resistance of three types of fracture fixation plates.

Authors:  Angela S P Lin; Chelsea M Fechter; Mark Magill; Felix Wipf; Thomas Moore; Robert E Guldberg
Journal:  J Orthop Surg Res       Date:  2016-09-26       Impact factor: 2.359

7.  Comparison of conventional reconstruction plate versus direct metal laser sintering plate: an in vitro mechanical characteristics study.

Authors:  Pusheng Xie; Hanbin Ouyang; Yuping Deng; Yang Yang; Jing Xu; Wenhua Huang
Journal:  J Orthop Surg Res       Date:  2017-09-02       Impact factor: 2.359

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.