Literature DB >> 18703954

Releasable suture technique.

Daniela S Monteiro de Barros1, Moataz E Gheith, Ghada A Siam, L Jay Katz.   

Abstract

PURPOSE: Releasable scleral flap sutures have been effectively used with trabeculectomy to provide a safer postoperative course. This review will assess the indications for using releasable sutures, with the consideration of their advantages and disadvantages, after trabeculectomy.
METHODS: A review of the literature provided the most common releasable suture techniques.
RESULTS: Releasable scleral flap sutures reduce the incidence of complications of early postoperative overfiltration after trabeculectomy. As a result, there are fewer cases that might require reformation of the anterior chamber and drainage of suprachoroidal fluid. In contrast to performing laser suture lysis; there is no need for a laser, suture visibility under the conjunctiva is irrelevant, and no contact lens is required.
CONCLUSIONS: The use of releasable scleral flap sutures in guarded filtration surgery safely provides an effective and simple way of titrating intraocular pressure postoperatively. It allows the transition from a relatively low flow state to a higher rate of subconjunctival filtration to achieve a satisfactory long-term outcome of glaucoma surgery.

Entities:  

Mesh:

Year:  2008        PMID: 18703954     DOI: 10.1097/IJG.0b013e31817d2399

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  4 in total

1.  The effect of adjustable suture (Khaw) trabeculectomy on intraocular pressure: a retrospective case series.

Authors:  Ahmet Kaplan; Tolga Kocatürk; Volkan Dayanır
Journal:  Int Ophthalmol       Date:  2015-05-23       Impact factor: 2.031

Review 2.  A novel suturing technique for filtering glaucoma surgery: the accordion suture.

Authors:  Mehmet Baykara; Basak Can Ermerak; Huri Sabur; Selim Genc
Journal:  Int J Ophthalmol       Date:  2017-12-18       Impact factor: 1.779

3.  The Influence of Scleral Flap Thickness, Shape, and Sutures on Intraocular Pressure (IOP) and Aqueous Humor Flow Direction in a Trabeculectomy Model.

Authors:  Amir Samsudin; Ian Eames; Steve Brocchini; Peng Tee Khaw
Journal:  J Glaucoma       Date:  2016-07       Impact factor: 2.503

4.  Comparative study of trabeculectomy using single sutures versus releasable sutures.

Authors:  Juliane Matlach; Niels Hoffmann; Florentina J Freiberg; Franz Grehn; Thomas Klink
Journal:  Clin Ophthalmol       Date:  2012-07-06