Literature DB >> 18703249

Lung 4D-IMRT treatment planning: an evaluation of three methods applied to four-dimensional data sets.

Eric D Ehler1, Wolfgang A Tomé.   

Abstract

PURPOSE: To compare 4D-dose distributions for IMRT planning on three data sets: a single 4D-CT phase, a 4D-CT phase with a density override to the tumor motion envelope (TME) volume, and the average intensity projection (AIP).
METHODS: Eight planning cases were considered. IMRT inverse planning optimization was performed on each of the three data set types, for each case considered. The plans were then applied to all ten phases of the associated 4D-CT data set. The dose to the GTV in each breathing phase was compared to the TME dose from the optimized dose distribution, as well as the GTV dose determined from a model-based deformable registration algorithm.
RESULTS: IMRT optimization on a single 3D data set resulted in a greater equivalent uniform dose (EUD) to the GTV when applied to a 4D-CT data set than the EUD for the TME in the optimized plan. The difference was up to 5.5Gy in one case. For all cases and planning techniques considered, a maximum difference of 0.3Gy in the NTDmean to the healthy lung throughout the breathing cycle was found.
CONCLUSIONS: For tumors located in the periphery of the lung, optimization on the AIP image resulted in a more uniform GTV dose throughout the breathing cycle. Averages in GTV EUD and healthy lung NTDmean taken over all the breathing phases were found to be in agreement with the dose effect parameters obtained from model-based deformable registration algorithms. All planning methods yielded GTV EUD values that were larger than the prescribed dose when the full 4D data set was considered.

Entities:  

Mesh:

Year:  2008        PMID: 18703249     DOI: 10.1016/j.radonc.2008.07.004

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  8 in total

1.  Motion management strategies and technical issues associated with stereotactic body radiotherapy of thoracic and upper abdominal tumors: A review from NRG oncology.

Authors:  Edward D Brandner; Indrin J Chetty; Tawfik G Giaddui; Ying Xiao; M Saiful Huq
Journal:  Med Phys       Date:  2017-04-20       Impact factor: 4.071

2.  Effect of breathing motion on radiotherapy dose accumulation in the abdomen using deformable registration.

Authors:  Michael Velec; Joanne L Moseley; Cynthia L Eccles; Tim Craig; Michael B Sharpe; Laura A Dawson; Kristy K Brock
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-08-21       Impact factor: 7.038

3.  Evaluating which plan quality metrics are appropriate for use in lung SBRT.

Authors:  Ravindra Yaparpalvi; Madhur K Garg; Jin Shen; William R Bodner; Dinesh K Mynampati; Aleiya Gafar; Hsiang-Chi Kuo; Amar K Basavatia; Nitin Ohri; Linda X Hong; Shalom Kalnicki; Wolfgang A Tome
Journal:  Br J Radiol       Date:  2018-01-10       Impact factor: 3.039

4.  The utilization of consistency metrics for error analysis in deformable image registration.

Authors:  Edward T Bender; Wolfgang A Tomé
Journal:  Phys Med Biol       Date:  2009-08-28       Impact factor: 3.609

5.  The effect of density overrides on magnetic resonance-guided radiation therapy planning for lung cancer.

Authors:  Oliver Schrenk; Claudia Katharina Spindeldreier; Daniela Schmitt; Falk Roeder; Mark Bangert; Lucas Norberto Burigo; Asja Pfaffenberger
Journal:  Phys Imaging Radiat Oncol       Date:  2018-11-22

6.  Account for the Full Extent of Esophagus Motion in Radiation Therapy Planning: A Preliminary Study of the IRV of the Esophagus.

Authors:  Aihui Feng; Hengle Gu; Hua Chen; Yan Shao; Hao Wang; Yanhua Duan; Ying Huang; Tao Zhou; Zhiyong Xu
Journal:  Front Oncol       Date:  2021-11-25       Impact factor: 6.244

7.  VMAT-SBRT planning based on an average intensity projection for lung tumors located in close proximity to the diaphragm: a phantom and clinical validity study.

Authors:  Shingo Ohira; Yoshihiro Ueda; Misaki Hashimoto; Masayoshi Miyazaki; Masaru Isono; Hiroshi Kamikaseda; Akira Masaoka; Masaaki Takashina; Masahiko Koizumi; Teruki Teshima
Journal:  J Radiat Res       Date:  2015-09-28       Impact factor: 2.724

8.  Efficacy evaluation of retrospectively applying the Varian normal breathing predictive filter for volume definition and artifact reduction in 4D CT lung patients.

Authors:  Ciaran Malone; Luke Rock; Christina Skourou
Journal:  J Appl Clin Med Phys       Date:  2014-05-08       Impact factor: 2.102

  8 in total