Literature DB >> 18703184

Evaluation of the Stryker S2 IM Nail Distal Targeting Device for reduction of radiation exposure: a case series study.

George Anastopoulos1, Panagiotis G Ntagiopoulos, Dionisios Chissas, George Loupasis, Antonios Asimakopoulos, Eustratios Athanaselis, Panagiotis Megas.   

Abstract

Distal locking is one challenging step during intramedullary nailing of femoral shaft fractures that can lead to an increase of radiation exposure. In the present study, the authors describe a technique for the distal locking of femoral nails, implementing a new targeting device in an attempt to reduce radiation exposure and operational time. Over a 2-year period, 127 consecutive cases of femoral shaft fractures were included in the study. All cases were treated with nailing of femoral shaft fractures with an unslotted reamed antegrade femoral nail and distal locking was performed with the use of a proximally mounted aiming device. Mean duration of the procedure was 63.5 18.1 min while the duration for distal locking was 6.6 +/- 2.6 min. In all successful cases, exposure from intraoperative fluoroscopy was 17.2 +/- 7.4 s for the whole operative procedure, and for distal locking was 2 shots, 1.35 s (range, 0.9-2.2 s) and 1.9 mGy (range, 1.1-2.9 mGy). Five cases (3.9%) were unsuccessful, but overall no intraoperative complications were encountered from the application of this technique. The ability of the device to correspond to the level of nail deformation and to properly identify the distal holes, reduced exposure to radiation compared to other published reports, and should be considered as a valuable tool for distal locking of femoral fractures.

Entities:  

Mesh:

Year:  2008        PMID: 18703184     DOI: 10.1016/j.injury.2008.04.020

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  5 in total

1.  [Suprapatellar approach to tibial medullary nailing with electromagnetic field-guided distal locking].

Authors:  J M Rueger; A H Rücker; M Hoffmann
Journal:  Unfallchirurg       Date:  2015-04       Impact factor: 1.000

Review 2.  Meta-analysis suggests that the electromagnetic technique is better than the free-hand method for the distal locking during intramedullary nailing procedures.

Authors:  Yanbin Zhu; Hengrui Chang; Yiyang Yu; Wei Chen; Song Liu; Yingze Zhang
Journal:  Int Orthop       Date:  2016-06-02       Impact factor: 3.075

3.  Fluoroscopic freehand and electromagnetic-guided targeting system for distal locking screws of humeral intramedullary nail.

Authors:  P Persiani; M Gurzi; O Moreschini; G Di Giacomo; C Villani
Journal:  Musculoskelet Surg       Date:  2016-11-22

4.  A distal-lock electromagnetic targeting device for intramedullary nailing: Suggestions and clinical experience.

Authors:  Guido Antonini; Wilfried Stuflesser; Cornelio Crippa; Georgios Touloupakis
Journal:  Chin J Traumatol       Date:  2016-12-01

5.  Comparison of free-hand fluoroscopic guidance and electromagnetic navigation in distal locking of tibia intramedullary nails.

Authors:  Yinsheng Wang; Bing Han; Zhigang Shi; Yu Fu; Yong Ye; Juehua Jing; Jun Li
Journal:  Medicine (Baltimore)       Date:  2018-07       Impact factor: 1.889

  5 in total