Literature DB >> 1870027

Telemeterized in vivo hip joint force data: a report on two patients after total hip surgery.

G M Kotzar1, D T Davy, V M Goldberg, K G Heiple, J Berilla, K G Heiple, R H Brown, A H Burstein.   

Abstract

Two telemeterized femoral components were implanted in two patients as part of normal total hip replacement procedures. The two components were instrumented to measure the three force components directed along: (a) the neck axis, (b) transverse to the neck axis and in the plane of the prosthesis, and (c) transverse to the neck axis and perpendicular to the plane of the prosthesis. Data were collected at multiple sessions during the early postoperative period for a number of standard activities, including gait, stair climbing, rising from a chair, single leg stance, double leg stance, ipsilateral and contralateral straight leg lifts while supine, ipsilateral flexion and extension while standing, and ipsilateral abduction while standing and lying on the contralateral side. These data are summarized and compared with the published results from analytic studies and with the results from previous studies using instrumented femoral components. Peak loads for gait during the period of study were roughly 2.7 body weights (BW) when the patients walked at their normal pace. Contact forces at the hip during stationary single leg stance approximated the peak loads during gait with values ranging from 2.1 to 2.8 BW. The highest forces recorded reached values approaching 5.5 BW and occurred during periods of instability while the patient engaged in stationary single leg stance. Our in vivo data indicate that forces generated during the above activities increase in magnitude quite rapidly during the early postoperative period and that during this period the patients have the ability to perform the activities of daily living without generating the high amplitude joint contact forces suggested by the results of dynamic studies. Joint contact forces during gait were found to depend on speed, but the high absolute magnitudes predicted by model studies were not supported by the in vivo data.

Entities:  

Mesh:

Year:  1991        PMID: 1870027     DOI: 10.1002/jor.1100090502

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  23 in total

Review 1.  Whole bone mechanics and bone quality.

Authors:  Jacqueline H Cole; Marjolein C H van der Meulen
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

2.  Stability of fused versus nonfused THA femoral impaction grafts.

Authors:  Anneliese D Heiner; John J Callaghan; Thomas D Brown
Journal:  J Orthop Res       Date:  2007-03       Impact factor: 3.494

3.  Stability differentials for proximal vs distal fusion of total hip arthroplasty femoral impaction grafts.

Authors:  Anneliese D Heiner; John J Callaghan; Thomas D Brown
Journal:  J Arthroplasty       Date:  2008-01-24       Impact factor: 4.757

4.  Effects of episodic subluxation events on third body ingress and embedment in the THA bearing surface.

Authors:  Anneliese D Heiner; Hannah J Lundberg; Thomas E Baer; Douglas R Pedersen; John J Callaghan; Thomas D Brown
Journal:  J Biomech       Date:  2008-06-17       Impact factor: 2.712

5.  Periacetabular reconstruction with a new endoprosthesis.

Authors:  Lawrence R Menendez; Elke R Ahlmann; Yuri Falkinstein; Daniel C Allison
Journal:  Clin Orthop Relat Res       Date:  2009-08-20       Impact factor: 4.176

6.  Biomechanics of the hip: forces exerted during walking.

Authors:  T Quesnel; P M Gueritey; G P Gonon
Journal:  Surg Radiol Anat       Date:  1995       Impact factor: 1.246

7.  Temporal and spatial distributions of directional counterface motion at the acetabular bearing surface in total hip arthroplasty.

Authors:  D R Pedersen; T D Brown; T A Maxian; J J Callaghan
Journal:  Iowa Orthop J       Date:  1998

Review 8.  Joint contact stress: a reasonable surrogate for biological processes?

Authors:  Richard A Brand
Journal:  Iowa Orthop J       Date:  2005

9.  Hip joint contact force in the emu (Dromaius novaehollandiae) during normal level walking.

Authors:  Jessica E Goetz; Timothy R Derrick; Douglas R Pedersen; Duane A Robinson; Michael G Conzemius; Thomas E Baer; Thomas D Brown
Journal:  J Biomech       Date:  2008-01-18       Impact factor: 2.712

10.  The effect of abductor muscle and anterior-posterior hip contact load simulation on the in-vitro primary stability of a cementless hip stem.

Authors:  Youngbae Park; Carolyne Albert; Yong-San Yoon; Göran Fernlund; Hanspeter Frei; Thomas R Oxland
Journal:  J Orthop Surg Res       Date:  2010-06-24       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.