Literature DB >> 18697709

Variation in segmentation of bone from micro-CT imaging: implications for quantitative morphometric analysis.

I H Parkinson1, A Badiei, N L Fazzalari.   

Abstract

Segmentation of bone in grey-level tomographs from micro-CT imaging is critical in determining the accuracy of morphometric analysis. The degree of variability in image segmentation between and within multiple operators will be quantified and compared with automated image segmentation. Three cubes of cancellous bone were cut from T12, L1, L3 and L4 human vertebral bodies (n=12). Micro-CT imaging was performed and a global threshold was determined by 3 operators independently and automatically using Otsu's algorithm. Bone volume, trabecular thickness, trabecular separation, trabecular number, trabecular bone pattern factor, structure model index and degree of anisotropy were calculated. Percent bias and percent random error were calculated between all operators and Otsu's method. For BV/TV, the maximum percent bias and percent random error were 22.0% and 11.3%, respectively, which constitutes differences in individual measurements between operators of up to 0.07. For Tb.Th, the maximum percent bias and percent random error were 13.1% and 6.4%, respectively, which constitutes differences in individual measurements between operators of up to 35 microm. These data highlight to users of micro-CT imaging that morphometric analysis is highly sensitive to operating parameters. The effect on measurements of cancellous bone structure of different operators can be greater than experimental differences, which can lead to erroneous interpretation of results.

Entities:  

Mesh:

Year:  2008        PMID: 18697709     DOI: 10.1007/bf03178592

Source DB:  PubMed          Journal:  Australas Phys Eng Sci Med        ISSN: 0158-9938            Impact factor:   1.430


  6 in total

1.  Measurement error in μCT-based three-dimensional geometric morphometrics introduced by surface generation and landmark data acquisition.

Authors:  Karolin Engelkes; Jennice Helfsgott; Jörg U Hammel; Sebastian Büsse; Thomas Kleinteich; André Beerlink; Stanislav N Gorb; Alexander Haas
Journal:  J Anat       Date:  2019-05-07       Impact factor: 2.610

Review 2.  Finite Element-Based Mechanical Assessment of Bone Quality on the Basis of In Vivo Images.

Authors:  Dieter H Pahr; Philippe K Zysset
Journal:  Curr Osteoporos Rep       Date:  2016-12       Impact factor: 5.096

3.  Quantitative analysis of bone and soft tissue by micro-computed tomography: applications to ex vivo and in vivo studies.

Authors:  Graeme M Campbell; Antonia Sophocleous
Journal:  Bonekey Rep       Date:  2014-08-20

4.  A simple rocker-induced mechanical stimulus upregulates mineralization by human osteoprogenitor cells in fibrous scaffolds.

Authors:  Sasima Puwanun; Robin M Delaine-Smith; Helen E Colley; Julian M Yates; Sheila MacNeil; Gwendolen C Reilly
Journal:  J Tissue Eng Regen Med       Date:  2017-08-09       Impact factor: 3.963

5.  How image-processing parameters can influence the assessment of dental materials using micro-CT.

Authors:  Fernanda Ferrari Esteves Torres; Reinhilde Jacobs; Mostafa EzEldeen; Karla de Faria-Vasconcelos; Juliane Maria Guerreiro-Tanomaru; Bernardo Camargo Dos Santos; Mário Tanomaru-Filho
Journal:  Imaging Sci Dent       Date:  2020-06-18

Review 6.  X-ray computed tomography and its potential in ecological research: A review of studies and optimization of specimen preparation.

Authors:  Yeisson Gutiérrez; David Ott; Mareike Töpperwien; Tim Salditt; Christoph Scherber
Journal:  Ecol Evol       Date:  2018-07-06       Impact factor: 2.912