CT-ED conversion on a GE Lightspeed-RT scanner: influence of scanner settings.

M A Ebert1, J Lambert, P B Greer.   

Abstract

The influence of tube voltage (kV) and current (mA) on the resulting relationship of computed tomography number to electron density (CT-ED) was investigated for a wide-bore GE scanner. The influence of kV and mA scan settings were examined in combination with a 16-bit image reconstruction algorithm made available via the scanner software and which allowed resolution of CT numbers for high density materials. By using titanium and stainless steel inserts in an electron density phantom, mA variation was found to have minimal impact on the CT-ED relationship, whereas variation in kV led to significant differences in CT number for the high density materials. The scanner is also equipped with automatic tube-current modulation capabilities. The influence of automatic tube-current modulation on CT number was investigated for a range of materials in a phantom geometry. It was found that tube current modulation has negligible effect on CT number, though the changing dimension of the phantom did influence CT number of an aluminium insert for scans undertaken with both fixed and modulated tube currents. In light of evidence from other studies examining the influence of CT number on dose calculation, it is recommended that scanner settings and specific CT-ED look-up tables be considered when calculations will be required with high-density materials present.

Entities:  

Mesh:

Year:  2008        PMID: 18697708     DOI: 10.1007/bf03178591

Source DB:  PubMed          Journal:  Australas Phys Eng Sci Med        ISSN: 0158-9938            Impact factor:   1.430


  6 in total

1.  Can CT scan protocols used for radiotherapy treatment planning be adjusted to optimize image quality and patient dose? A systematic review.

Authors:  Anne T Davis; Antony L Palmer; Andrew Nisbet
Journal:  Br J Radiol       Date:  2017-05-23       Impact factor: 3.039

2.  Application of Metal Implant 16-Bit Imaging: New Technique in Radiotherapy.

Authors:  Ni Xin-Ye; Gao Liugang; Fang Mingming; Lin Tao
Journal:  Technol Cancer Res Treat       Date:  2016-06-23

Review 3.  Computed tomography imaging parameters for inhomogeneity correction in radiation treatment planning.

Authors:  Indra J Das; Chee-Wai Cheng; Minsong Cao; Peter A S Johnstone
Journal:  J Med Phys       Date:  2016 Jan-Mar

4.  Effects of 16-bit CT imaging scanning conditions for metal implants on radiotherapy dose distribution.

Authors:  Liugang Gao; Hongfei Sun; Xinye Ni; Mingming Fang; Tao Lin
Journal:  Oncol Lett       Date:  2017-12-11       Impact factor: 2.967

5.  Impact of computed tomography (CT) reconstruction kernels on radiotherapy dose calculation.

Authors:  Irina Vergalasova; Michael McKenna; Ning Jeff Yue; Meral Reyhan
Journal:  J Appl Clin Med Phys       Date:  2020-09-05       Impact factor: 2.102

6.  The impact of mass density variations on an electron Monte Carlo algorithm for radiotherapy dose calculations.

Authors:  Raymond Fang; Thomas Mazur; Sasa Mutic; Rao Khan
Journal:  Phys Imaging Radiat Oncol       Date:  2018-11-02
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.