Literature DB >> 18697704

The effective atomic number of dosimetric gels.

M L Taylor1, R D Franich, J V Trapp, P N Johnston.   

Abstract

Radiological properties of gel dosimeters and phantom materials are often compared against each other and against water or tissue by consideration parameters including their effective atomic number, Zeff. Effective atomic numbers have been calculated for a range of ferrous-sulphate and polymeric gel dosimeters using mass attenuation coefficient data over the energy range 10 keV to 10 MeV. Data is presented relative to water to allow direct comparison over a range of energies. These data provide energy specific values of Zeff which improves on the practice of applying a power-law based formula to estimate an energy independent value. For applications that require a single value of Zeff, the data presented here allows the choice of a value appropriate to the energy of the photon source or a spectrum-weighted average. Studying the variation of Zeff, which is equivalent to taking into account the variation of mass attenuation coefficients with photon energy, it is found that gels typically match water better than water matches human tissues. As such, the subtle differences in effective atomic number between water and gels are small and may be considered negligible. Consideration of the mean disparity over a large energy range shows, broadly, BANG-1 to be the most water equivalent gel.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18697704     DOI: 10.1007/bf03178587

Source DB:  PubMed          Journal:  Australas Phys Eng Sci Med        ISSN: 0158-9938            Impact factor:   1.430


  4 in total

1.  Gamma-ray attenuation properties of some NLO materials: potential use in dosimetry.

Authors:  M S Al-Buriahi; V P Singh; Halil Arslan; V V Awasarmol; Baris T Tonguc
Journal:  Radiat Environ Biophys       Date:  2019-11-28       Impact factor: 1.925

2.  Dose and slice thickness evaluation with nMAG gel dosimeters in computed tomography.

Authors:  Chun-Chao Chuang; Jay Wu
Journal:  Sci Rep       Date:  2018-02-08       Impact factor: 4.379

3.  Effective Atomic Number and Electron Density Determination for Fricke Gel Dosimeters Using Different Methods.

Authors:  Ouiza Moussous
Journal:  J Med Phys       Date:  2022-03-31

4.  Prevention of transfusion-associated graft-versus-host disease by irradiation: technical aspect of a new ferrous sulphate dosimetric system.

Authors:  Lucas Sacchini Del Lama; Evamberto Garcia de Góes; Paulo César Dias Petchevist; Edson Lara Moretto; José Carlos Borges; Dimas Tadeu Covas; Adelaide de Almeida
Journal:  PLoS One       Date:  2013-06-07       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.