Literature DB >> 18695415

Effective dose estimation in diagnostic radiology with two dosimeters: impact of the 2007 recommendations of the ICRP.

Heiner von Boetticher1, J Lachmund, W Hoffmann.   

Abstract

In many standard situations in radiation protection the effective dose is underestimated if it is based on the depth personal dose equivalent Hp(10) measured with a single dosimeter in the anterior thoracic region (chest) underneath the protective apron (Hp,c,u). The estimate can be significantly improved by inclusion of a second dosimeter worn on the front area of the neck over of the protective garment (Hp,n,o) representing organs and areas that are usually not completely covered by the protective garment. The recent recommendations of the International Commission on Radiological Protection (ICRP) emphasize the contribution of the head and neck region to the effective dose. This accentuates the need for a valid representation of this body region in the effective dose algorithm. In this paper we derived coefficients for the two-dosimeter situation using phantom measurements for selected radiological procedures with different geometries between patient and investigator. According to ICRP 60, the algorithm with {without} thyroid protection is E = 0.64{0.64} Hp,c,u + 0.016{0.073} Hp,n,o. According to ICRP 103, the algorithm becomes E = 0.60{0.60} Hp,c,u + 0.047{0.094} Hp,n,o. The ICRP 103 model reveals that the underestimation of the effective dose based on Hp(10) using a single dosimeter worn under the protective garment is even higher than previously assumed based on ICRP 60. Future personal dosimetry should be qualified by a two-dosimeter concept. The head and neck region which is not covered by a conventional protective garment needs to be protected by mounted shielding or other constructive measures.

Entities:  

Mesh:

Year:  2008        PMID: 18695415     DOI: 10.1097/01.HP.0000318877.79131.08

Source DB:  PubMed          Journal:  Health Phys        ISSN: 0017-9078            Impact factor:   1.316


  3 in total

Review 1.  Low dose CT of the heart: a quantum leap into a new era of cardiovascular imaging.

Authors:  E Maffei; C Martini; S De Crescenzo; T Arcadi; A Clemente; E Capuano; A Rossi; R Malagò; N Mollet; A Weustink; C Tedeschi; L La Grutta; S Seitun; A Igoren Guaricci; F Cademartiri
Journal:  Radiol Med       Date:  2010-06-23       Impact factor: 3.469

2.  Radiation exposure of medical staff from interventional x-ray procedures: a multicentre study.

Authors:  Uwe Häusler; Renate Czarwinski; Gunnar Brix
Journal:  Eur Radiol       Date:  2009-04-07       Impact factor: 5.315

3.  A Preliminary Survey of Women Orthopaedic Surgeons on Awareness of Radiation Safety Practice and Breast Cancer Risk in India.

Authors:  Ansu Thankam John; Vrisha Madhuri
Journal:  Indian J Orthop       Date:  2021-09-22       Impact factor: 1.033

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.